Literature DB >> 17043340

Device-associated nosocomial infections in 55 intensive care units of 8 developing countries.

Victor D Rosenthal1, Dennis G Maki, Reinaldo Salomao, Carlos Alvarez Moreno, Yatin Mehta, Francisco Higuera, Luis E Cuellar, Ozay Akan Arikan, Rédouane Abouqal, Hakan Leblebicioglu.   

Abstract

BACKGROUND: Health care-associated infections from invasive medical devices in the intensive care unit (ICU) are a major threat to patient safety. Most published studies of ICU-acquired infections have come from industrialized western countries. In a Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance (NNIS) System report, the U.S. pooled mean rates of central venous catheter (CVC)-related bloodstream infections, ventilator-associated pneumonia, and catheter-associated urinary tract infections were 4.0 per 1000 CVC days, 5.4 per 1000 mechanical ventilator days, and 3.9 per Foley catheter days, respectively.
OBJECTIVE: To ascertain the incidence of device-associated infections in the ICUs of developing countries.
DESIGN: Multicenter, prospective cohort surveillance of device-associated infection by using the CDC NNIS System definitions.
SETTING: 55 ICUs of 46 hospitals in Argentina, Brazil, Colombia, India, Mexico, Morocco, Peru, and Turkey that are members of the International Nosocomial Infection Control Consortium (INICC). MEASUREMENTS: Rates of device-associated infection per 100 patients and per 1000 device days.
RESULTS: During 2002-2005, 21,069 patients who were hospitalized in ICUs for an aggregate 137,740 days acquired 3095 device-associated infections for an overall rate of 14.7% or 22.5 infections per 1000 ICU days. Ventilator-associated pneumonia posed the greatest risk (41% of all device-associated infections or 24.1 cases [range, 10.0 to 52.7 cases] per 1000 ventilator days), followed by CVC-related bloodstream infections (30% of all device-associated infections or 12.5 cases [range, 7.8 to 18.5 cases] per 1000 catheter days) and catheter-associated urinary tract infections (29% of all device-associated infections or 8.9 cases [range, 1.7 to 12.8 cases] per 1000 catheter days). Notably, 84% of Staphylococcus aureus infections were caused by methicillin-resistant strains, 51% of Enterobacteriaceae isolates were resistant to ceftriaxone, and 59% of Pseudomonas aeruginosa isolates were resistant to fluoroquinolones. The crude mortality rate for patients with device-associated infections ranged from 35.2% (for CVC-associated bloodstream infection) to 44.9% (for ventilator-associated pneumonia). LIMITATIONS: These initial data are not adequate to represent any entire country, and likely variations in the efficiency of surveillance and institutional resources may have affected the rates that were detected.
CONCLUSIONS: Device-associated infections in the ICUs of these developing countries pose greater threats to patient safety than in U.S. ICUs. Active infection control programs that perform surveillance of infection and implement guidelines for prevention can improve patient safety and must become a priority in every country.

Entities:  

Mesh:

Year:  2006        PMID: 17043340     DOI: 10.7326/0003-4819-145-8-200610170-00007

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  96 in total

1.  How should long-term tunneled central venous catheters be managed in microbiology laboratories in order to provide an accurate diagnosis of colonization?

Authors:  M Guembe; P Martín-Rabadán; A Echenagusia; F Camúñez; G Rodríguez-Rosales; G Simó; M Echenagusia; E Bouza
Journal:  J Clin Microbiol       Date:  2011-12-14       Impact factor: 5.948

2.  In vitro potency and in vivo efficacy of a novel bis-indole antimicrobial compound in reducing catheter colonization.

Authors:  Mohammad D Mansouri; Timothy J Opperman; John D Williams; Charles Stager; Rabih O Darouiche
Journal:  Antimicrob Agents Chemother       Date:  2012-01-23       Impact factor: 5.191

3.  Impact of a multidimensional infection control strategy on catheter-associated urinary tract infection rates in the adult intensive care units of 15 developing countries: findings of the International Nosocomial Infection Control Consortium (INICC).

Authors:  V D Rosenthal; S K Todi; C Álvarez-Moreno; M Pawar; A Karlekar; A A Zeggwagh; Z Mitrev; F E Udwadia; J A Navoa-Ng; M Chakravarthy; R Salomao; S Sahu; A Dilek; S S Kanj; H Guanche-Garcell; L E Cuéllar; G Ersoz; A Nevzat-Yalcin; N Jaggi; E A Medeiros; G Ye; Ö A Akan; T Mapp; A Castañeda-Sabogal; L Matta-Cortés; F Sirmatel; N Olarte; H Torres-Hernández; N Barahona-Guzmán; R Fernández-Hidalgo; W Villamil-Gómez; D Sztokhamer; S Forciniti; R Berba; H Turgut; C Bin; Y Yang; I Pérez-Serrato; C E Lastra; S Singh; D Ozdemir; S Ulusoy
Journal:  Infection       Date:  2012-06-19       Impact factor: 3.553

4.  Mechanism of inactivation of influenza viruses by immobilized hydrophobic polycations.

Authors:  Bryan B Hsu; Sze Yinn Wong; Paula T Hammond; Jianzhu Chen; Alexander M Klibanov
Journal:  Proc Natl Acad Sci U S A       Date:  2010-12-20       Impact factor: 11.205

5.  Microbial colonization of electrocardiographic telemetry systems before and after cleaning.

Authors:  Alice Reshamwala; Kathryn McBroom; Yong Il Choi; Linda LaTour; Antoinette Ramos-Embler; Rowena Steele; Virginia Lomugdang; Margaret Newman; Colleen Reid; Yanfang Zhao; Bradi B Granger
Journal:  Am J Crit Care       Date:  2013-09       Impact factor: 2.228

Review 6.  Antibiotic use and emerging resistance: how can resource-limited countries turn the tide?

Authors:  Lisa M Bebell; Anthony N Muiru
Journal:  Glob Heart       Date:  2014-10-31

7.  Partial Depletion of Regulatory T Cells Enhances Host Inflammatory Response Against Acute Pseudomonas aeruginosa Infection After Sepsis.

Authors:  Zhi-Qiang Hu; Yong-Ming Yao; Wei Chen; Jia-Lan Bian; Lin-Jun Zhao; Long-Wang Chen; Guang-Liang Hong; Zhong-Qiu Lu; Guang-Ju Zhao
Journal:  Inflammation       Date:  2018-10       Impact factor: 4.092

8.  Sporadic isolations of a multi-drug resistant Pseudomonas aeruginosa clone during a 14-month epidemic in a general hospital in Hiroshima.

Authors:  S Kouda; Y Fujiue; Y Watanabe; M Ohara; S Kayama; F Kato; J Hisatsune; K Tsuruda; A Matsubara; M Doi; M Kuwabara; M Sugai
Journal:  Infection       Date:  2011-04-22       Impact factor: 3.553

Review 9.  Medically important bacterial-fungal interactions.

Authors:  Anton Y Peleg; Deborah A Hogan; Eleftherios Mylonakis
Journal:  Nat Rev Microbiol       Date:  2010-03-29       Impact factor: 60.633

10.  Health-care associated infections rates, length of stay, and bacterial resistance in an intensive care unit of Morocco: findings of the International Nosocomial Infection Control Consortium (INICC).

Authors:  Naoufel Madani; Victor D Rosenthal; Tarek Dendane; Khalid Abidi; Amine Ali Zeggwagh; Redouane Abouqal
Journal:  Int Arch Med       Date:  2009-10-07
View more