Literature DB >> 17038441

Sex-related effects on venous compliance and capillary filtration in the lower limb.

M Lindenberger1, T Länne.   

Abstract

Recent studies in humans have suggested sex differences in venous compliance of the lower limb, with lower compliance in women. Capillary fluid filtration could, however, be a confounder in the evaluation of venous compliance. The venous capacitance and capillary filtration response in the calves of 12 women (23.2 +/- 0.5 years) and 16 men (22.9 +/- 0.5 years) were studied during 8 min lower body negative pressure (LBNP) of 11, 22, and 44 mmHg. Calf venous compliance is dependent on pressure and was determined using the first derivative of a quadratic regression equation that described the capacitance-pressure relationship [compliance = beta1 + (2 x beta2 x transmural pressure)]. We found a lower venous compliance in women at low transmural pressures, and the venous capacitance in men was increased (P < 0.05). However, the difference in compliance between sexes was reduced and not seen at higher transmural pressures. Net capillary fluid filtration and capillary filtration coefficient (CFC) were greater in women than in men during LBNP (P < 0.05). Furthermore, calf volume increase (capacitance response + total capillary filtration) during LBNP was equivalent in both sexes. When total capillary filtration was not subtracted from the calf capacitance response in the calculation of venous compliance, the sex differences disappeared, emphasizing that venous compliance measurement should be corrected for the contribution of CFC.

Entities:  

Mesh:

Year:  2006        PMID: 17038441     DOI: 10.1152/ajpregu.00394.2006

Source DB:  PubMed          Journal:  Am J Physiol Regul Integr Comp Physiol        ISSN: 0363-6119            Impact factor:   3.619


  11 in total

Review 1.  Space physiology IV: mathematical modeling of the cardiovascular system in space exploration.

Authors:  M Keith Sharp; Jerry Joseph Batzel; Jean-Pierre Montani
Journal:  Eur J Appl Physiol       Date:  2013-03-29       Impact factor: 3.078

2.  Calf venous compliance measured by venous occlusion plethysmography: methodological aspects.

Authors:  Johan Skoog; Helene Zachrisson; Marcus Lindenberger; Mikael Ekman; Lea Ewerman; Toste Länne
Journal:  Eur J Appl Physiol       Date:  2014-10-02       Impact factor: 3.078

Review 3.  Cardiovascular sex differences influencing microvascular exchange.

Authors:  Virginia H Huxley; Jianjie Wang
Journal:  Cardiovasc Res       Date:  2010-05-21       Impact factor: 10.787

4.  How do walking, standing, and resting influence transtibial amputee residual limb fluid volume?

Authors:  Joan E Sanders; John C Cagle; Katheryn J Allyn; Daniel S Harrison; Marcia A Ciol
Journal:  J Rehabil Res Dev       Date:  2014

5.  Theoretical analysis of the mechanisms of a gender differentiation in the propensity for orthostatic intolerance after spaceflight.

Authors:  Richard L Summers; Steven Platts; Jerry G Myers; Thomas G Coleman
Journal:  Theor Biol Med Model       Date:  2010-03-18       Impact factor: 2.432

6.  Reduced Venous Compliance in Young Women with Type 1 Diabetes - Further Aggravated by Prolonged Elevated Levels of HbA1c.

Authors:  Marcus Lindenberger
Journal:  Front Endocrinol (Lausanne)       Date:  2016-09-21       Impact factor: 5.555

7.  Gender differences in tibial microvascular flow responses to head down tilt and lower body negative pressure.

Authors:  Jamila H Siamwala; Brandon R Macias; Paul C Lee; Alan R Hargens
Journal:  Physiol Rep       Date:  2017-02-27

8.  Slower Lower Limb Blood Pooling Increases Orthostatic Tolerance in Women with Vasovagal Syncope.

Authors:  Johan Skoog; Helene Zachrisson; Toste Länne; Marcus Lindenberger
Journal:  Front Physiol       Date:  2016-06-14       Impact factor: 4.566

9.  Decreased compliance in the deep and superficial conduit veins of the upper arm during prolonged cycling exercise.

Authors:  Anna Oue; Kohei Sato; Marina Yoneya; Tomoko Sadamoto
Journal:  Physiol Rep       Date:  2017-04

10.  Evaluating the efficacy of an active compression brace on orthostatic cardiovascular responses.

Authors:  Hadi Moein; Ramandeep Jhalli; Andrew P Blaber; Victoria E Claydon; Carlo Menon
Journal:  PLoS One       Date:  2017-11-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.