Literature DB >> 17038409

Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time-density curve for the aorta, portal vein and liver.

F Tatsugami1, M Matsuki, Y Inada, G Nakai, M Tanikake, S Yoshikawa, I Narabayashi.   

Abstract

The effects of saline pushing after contrast material injection were investigated as well as the possibility for this technique to reduce contrast material doses in liver CT examinations. 52 patients were divided randomly into three groups: 100 ml of contrast material (300 mg I ml(-1)) only (A; n = 19), 100 ml of contrast material pushed with 50 ml of saline solution (B; n = 17), and 85 ml of contrast material pushed with 50 ml of saline solution (C; n = 16). Single-level images were obtained at the level of the main portal vein after the initiation of contrast material injection. There were no significant differences in the mean peak enhancement values (PE) and the mean time to peak enhancement values (TPE) of the aorta between the three groups. The mean PE of the portal vein in group B increased 21 HU over that in group A (p<0.05), and there was no significant difference between groups A and C. The mean PE of the liver in group B increased 7 HU over that in group A (p<0.05), and there was no significant difference between groups A and C. The mean TPE of the portal vein was shorter by 4 s (p<0.05), and that of the liver was shorter by 5 s (p<0.05) in group C compared with those in group A. In conclusion, saline pushing increases the enhancement values of the portal vein and liver, and allows a contrast material dose reduction of 15 ml without decreasing hepatic and vascular enhancement at adequate scan timing.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17038409     DOI: 10.1259/bjr/60407135

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

1.  Optimal injection method for long-range computed tomography angiography.

Authors:  Aogu Yamaguchi; Tsukasa Sasaki
Journal:  Radiol Phys Technol       Date:  2017-06-01

2.  Proposal of a novel protocol using estimated cardiac index fractional dose to improve aortic contrast enhancement for early-phase dynamic CT.

Authors:  Tadashi Kuba; Akihiro Tokushige; Sadayuki Murayama; Shinichiro Ueda
Journal:  Medicine (Baltimore)       Date:  2022-06-24       Impact factor: 1.817

3.  Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

Authors:  D Violon
Journal:  Br J Radiol       Date:  2012-12       Impact factor: 3.039

  3 in total