Literature DB >> 1703189

Detection by immunofluorescence of surface molecules present in low copy numbers. High sensitivity staining and calibration of flow cytometer.

H Zola1, S H Neoh, B X Mantzioris, J Webster, M S Loughnan.   

Abstract

Receptors for lymphokines and growth factors are present on cell surfaces often at concentrations of 100-500 copies per cell. Although conventional immunofluorescence cannot detect such low levels, cell membrane antigens present at these concentrations can be detected using an optimally set up flow cytometer together with a three-layer immunofluorescence technique, consisting of monoclonal antibody reacted with selected batches of biotinylated horse anti-mouse immunoglobulin and phycoerythrin-streptavidin. In this study we purified and radiolabelled a number of monoclonal antibodies, determined the specific radioactivity by self-displacement analysis, and used the radiolabelled antibody in experiments where the number of molecules of antibody bound per cell and the fluorescence intensity were measured on the same sample. This permitted us to determine the sensitivity of the fluorescence procedure in molecules per cell, using several different antibody/target cell combinations. The method was consistently capable of detecting fewer than 100 molecules of antibody bound per cell.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1703189     DOI: 10.1016/0022-1759(90)90278-4

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  8 in total

1.  A simple corneal perfusion chamber for drug penetration and toxicity studies.

Authors:  M A Thiel; N Morlet; D Schulz; H F Edelhauser; J K Dart; D J Coster; K A Williams
Journal:  Br J Ophthalmol       Date:  2001-04       Impact factor: 4.638

2.  Penetration of engineered antibody fragments into the eye.

Authors:  M A Thiel; D J Coster; S D Standfield; H M Brereton; C Mavrangelos; H Zola; S Taylor; A Yusim; K A Williams
Journal:  Clin Exp Immunol       Date:  2002-04       Impact factor: 4.330

3.  The use of four-colour immunofluorescence techniques to identify mesenchymal stem cells.

Authors:  Matthias Schieker; Christoph Pautke; Katharina Reitz; Indradeo Hemraj; Peter Neth; Wolf Mutschler; Stefan Milz
Journal:  J Anat       Date:  2004-02       Impact factor: 2.610

4.  Influence of format on in vitro penetration of antibody fragments through porcine cornea.

Authors:  H M Brereton; S D Taylor; A Farrall; D Hocking; M A Thiel; M Tea; D J Coster; K A Williams
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

Review 5.  Flow cytometry. Principles and applications in exercise immunology.

Authors:  H Gabriel; W Kindermann
Journal:  Sports Med       Date:  1995-11       Impact factor: 11.136

6.  Expression of interleukin-6 receptor on blood lymphocytes without in vitro activation.

Authors:  H Zola; L Flego
Journal:  Immunology       Date:  1992-06       Impact factor: 7.397

7.  Immunohistological assessment of cutaneous drug hypersensitivity in patients with HIV infection.

Authors:  A Carr; E Vasak; V Munro; R Penny; D A Cooper
Journal:  Clin Exp Immunol       Date:  1994-08       Impact factor: 4.330

8.  Phase I study of intravenously applied bispecific antibody in renal cell cancer patients receiving subcutaneous interleukin 2.

Authors:  B J Kroesen; J Buter; D T Sleijfer; R A Janssen; W T van der Graaf; T H The; L de Leij; N H Mulder
Journal:  Br J Cancer       Date:  1994-10       Impact factor: 7.640

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.