Literature DB >> 17031454

MR-compatible assistance system for punction in a high-field system: device and feasibility of transgluteal biopsies of the prostate gland.

Stephan Zangos1, Christopher Herzog, Katrin Eichler, Renate Hammerstingl, Andreas Lukoschek, Stefanie Guthmann, Bernd Gutmann, Uwe Joseph Schoepf, Phillip Costello, Thomas J Vogl.   

Abstract

We present the first cadavic study results concerning the feasibility of the use of an MR-guided assistance system, Innomotion (Innomedic, Herxheim, Germany), for accurate and consistent placement of percutaneous needles in the prostate gland. The MR-compatible assistance system consists of a C-arch, guiding arm and application module (AMO). T1-weighted fast low angle shot (FLASH) 2-D-GRE sequence (TR/TE=110/4 ms) and T2-weighted turbo spin-echo (TSE)-sequences (TR/TE=3200/97 ms) in transversal orientation were used for the monitoring of the punction of the prostate gland. Planning and control of the intervention is to be made outside the scanner room on a desktop computer that receives DICOM images from the scanner. Servopneumatic drives move the AMO to the insertion point. The physician has to introduce the punction needle manually. The mean deviation of the needle tip to the target in a gel phantom was 0.35 mm. An accurate punction of the prostate gland can easily be performed using this system with a transgluteal access. The T2-weighted images are superior for the evaluation of the prostate anatomy and the needle position during the interventions. In conclusion, our preliminary results indicate that this MR-guided assistance system is suitable for an accurate transgluteal needle placement in the prostate.

Mesh:

Year:  2006        PMID: 17031454     DOI: 10.1007/s00330-006-0421-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  37 in total

Review 1.  Review of staging modalities in clinically localized prostate cancer.

Authors:  M Perrotti; A Pantuck; F Rabbani; R S Israeli; R E Weiss
Journal:  Urology       Date:  1999-08       Impact factor: 2.649

2.  Real time MRI-ultrasound image guided stereotactic prostate biopsy.

Authors:  Irving Kaplan; Nicklas E Oldenburg; Paul Meskell; Michael Blake; Paul Church; Edward J Holupka
Journal:  Magn Reson Imaging       Date:  2002-04       Impact factor: 2.546

3.  Prostatic biopsy after proctocolectomy: a transgluteal, CT-guided approach.

Authors:  N Papanicolaou; P J Eisenberg; S G Silverman; M M McNicholas; A F Althausen
Journal:  AJR Am J Roentgenol       Date:  1996-06       Impact factor: 3.959

4.  Detection of extracapsular extension of prostate carcinoma with endorectal and phased-array coil MR imaging: multivariate feature analysis.

Authors:  K K Yu; H Hricak; R Alagappan; D M Chernoff; P Bacchetti; C J Zaloudek
Journal:  Radiology       Date:  1997-03       Impact factor: 11.105

5.  Image-guided robotic delivery system for precise placement of therapeutic agents.

Authors:  K Cleary; M Freedman; M Clifford; D Lindisch; S Onda; L Jiang
Journal:  J Control Release       Date:  2001-07-06       Impact factor: 9.776

6.  MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results.

Authors:  Stephan Zangos; Katrin Eichler; Kerstin Engelmann; Mukhtiar Ahmed; Sebastian Dettmer; Christopher Herzog; Wasilios Pegios; A Wetter; Thomas Lehnert; Martin G Mack; Thomas J Vogl
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

7.  T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging.

Authors:  Tsutomu Tamada; Teruki Sone; Kiyohisa Nagai; Yoshimasa Jo; Masayuki Gyoten; Shigeki Imai; Yasumasa Kajihara; Masao Fukunaga
Journal:  Eur Radiol       Date:  2003-10-18       Impact factor: 5.315

8.  The National Cancer Data Base report on prostate carcinoma after the peak in incidence rates in the U.S. The American College of Surgeons Commission on Cancer and the American Cancer Society.

Authors:  C J Mettlin; G P Murphy; D S Rosenthal; H R Menck
Journal:  Cancer       Date:  1998-10-15       Impact factor: 6.860

9.  The appearance of prostate cancer on transrectal ultrasonography: correlation of imaging and pathological examinations.

Authors:  K Shinohara; T M Wheeler; P T Scardino
Journal:  J Urol       Date:  1989-07       Impact factor: 7.450

10.  The significance of isoechoic prostatic carcinoma.

Authors:  W J Ellis; M K Brawer
Journal:  J Urol       Date:  1994-12       Impact factor: 7.450

View more
  20 in total

Review 1.  Robotic prostate biopsy and its relevance to focal therapy of prostate cancer.

Authors:  Henry Ho; John S P Yuen; Christopher W S Cheng
Journal:  Nat Rev Urol       Date:  2011-09-20       Impact factor: 14.432

2.  An MRI-compatible robotic system with hybrid tracking for MRI-guided prostate intervention.

Authors:  Axel Krieger; Iulian I Iordachita; Peter Guion; Anurag K Singh; Aradhana Kaushal; Cynthia Ménard; Peter A Pinto; Kevin Camphausen; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2011-11       Impact factor: 4.538

Review 3.  MR-guided prostate interventions.

Authors:  Clare Tempany; Sarah Straus; Nobuhiko Hata; Steven Haker
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

4.  Robotic image-guided needle interventions of the prostate.

Authors:  Pierre C Mozer; Alan W Partin; Dan Stoianovici
Journal:  Rev Urol       Date:  2009

5.  [Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer].

Authors:  M Schernthaner; T H Helbich; B J Fueger; M Margreiter; M Memarsadeghi; A Stiglbauer; H-G Linhart; A Doan; K Pinker; P Brader
Journal:  Radiologe       Date:  2011-11       Impact factor: 0.635

6.  A Passive Parallel Master-Slave Mechanism for Magnetic Resonance Imaging-Guided Interventions.

Authors:  Santhi Elayaperumal; Mark R Cutkosky; Pierre Renaud; Bruce L Daniel
Journal:  J Med Device       Date:  2015-03       Impact factor: 0.582

7.  MR Safe Robot, FDA Clearance, Safety and Feasibility Prostate Biopsy Clinical Trial.

Authors:  Dan Stoianovici; Chunwoo Kim; Doru Petrisor; Changhan Jun; Sunghwan Lim; Mark W Ball; Ashley Ross; Katarzyna J Macura; Mohamad Allaf
Journal:  IEEE ASME Trans Mechatron       Date:  2016-10-20       Impact factor: 5.303

8.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention.

Authors:  Axel Krieger; Sang-Eun Song; Nathan B Cho; Iulian Iordachita; Peter Guion; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE ASME Trans Mechatron       Date:  2011-10-17       Impact factor: 5.303

Review 9.  Advancements in magnetic resonance-guided robotic interventions in the prostate.

Authors:  Katarzyna J Macura; Dan Stoianovici
Journal:  Top Magn Reson Imaging       Date:  2008-12

Review 10.  Urologic robots and future directions.

Authors:  Pierre Mozer; Jocelyne Troccaz; Dan Stoianovici
Journal:  Curr Opin Urol       Date:  2009-01       Impact factor: 2.309

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.