Literature DB >> 17028722

Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations.

Vishnupriya Bhakthavatsalam1, Alexey Shvarev, Eric Bakker.   

Abstract

Coulometry belongs to one of the few known calibration-free techniques and is therefore highly attractive for chemical analysis. Titrations performed by the coulometric generation of reactants is a well-known approach in electrochemistry, but suffers from limited selectivity and is therefore not generally suited for samples of varying or unknown composition. Here, the selective coulometric release of ionic reagents from ion-selective polymeric membrane materials ordinarily used for the fabrication of ion-selective electrodes is described. The selectivity of such membranes can be tuned to a significant extent by the type and concentration of ionophore and lipophilic ion-exchanger and is today well understood. An anodic current of fixed magnitude and duration may be imposed across such a membrane to release a defined quantity of ions with high selectivity and precision. Since the applied current relates to a defined ion flux, a variety of non-redox active ions may be accurately released with this technique. In this work, the released titrant's activity was measured with a second ionophore-based ion-selective electrode and corresponded well with expected dosage levels on the basis of Faraday's law of electrolysis. Initial examples of coulometric titrations explored here include the release of calcium ions for complexometric titrations, including back titrations, and the release of barium ions to determine sulfate.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17028722     DOI: 10.1039/b602906j

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Beyond potentiometry: robust electrochemical ion sensor concepts in view of remote chemical sensing.

Authors:  Eric Bakker; Vishnupriya Bhakthavatsalam; Kebede L Gemene
Journal:  Talanta       Date:  2007-10-18       Impact factor: 6.057

2.  Modern Directions for Potentiometric Sensors.

Authors:  Eric Bakker; Karin Chumbimuni-Torres
Journal:  J Braz Chem Soc       Date:  2008-01-01       Impact factor: 1.838

3.  Interpretation of chronopotentiometric transients of ion-selective membranes with two transition times.

Authors:  Justin M Zook; Sándor Bodor; Róbert E Gyurcsányi; Ernő Lindner
Journal:  J Electroanal Chem (Lausanne)       Date:  2010-01-15       Impact factor: 4.464

4.  Direct sensing of total acidity by chronopotentiometric flash titrations at polymer membrane ion-selective electrodes.

Authors:  Kebede L Gemene; Eric Bakker
Journal:  Anal Chem       Date:  2008-03-28       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.