Literature DB >> 17024839

Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction.

Jürgen J Scheins1, Fritz Boschen, Hans Herzog.   

Abstract

Use of iterative algorithms to reconstruct three-dimensional (3-D) positron emission tomography (PET) data requires the computation of the system probability matrix. The pure geometrical contribution can easily be approximated by the length-of-intersection (LOI) between lines-of-response (LOR) and individual voxels. However, more accurate geometrical projectors are desirable. Therefore, we have developed a fast method for the analytical calculation of the 3-D shape and volume of volumes-of-intersection (VOI). This method provides an alternative robust projector with a uniformly continuous sampling of the image space. The enhanced calculation effort is facilitated by using several speedup techniques. Exploiting intrinsic symmetry relations and the sparseness of the system matrix allows to create an efficiently compressed matrix which can be precomputed and completely stored in memory. In addition, a new voxel addressing scheme has been implemented. This scheme avoids time-consuming symmetry transformations of voxel addresses by using an octant-wise symmetrically ordered field of voxels. The above methods have been applied for a fully 3-D, iterative reconstruction of 3-D sinograms recorded with a Siemens/CTI ECAT HR+ PET scanner. A comparison of the performance of the reconstruction using LOI weighting and VOI weighting is presented.

Mesh:

Year:  2006        PMID: 17024839     DOI: 10.1109/tmi.2006.880679

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Finite detector based projection model for high spatial resolution.

Authors:  Hengyong Yu; Ge Wang
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

2.  Iterative reconstruction of Fourier-rebinned PET data using sinogram blurring function estimated from point source scans.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography.

Authors:  Krishnendu Saha; Kenneth J Straus; Yu Chen; Stephen J Glick
Journal:  J Appl Phys       Date:  2014-08-28       Impact factor: 2.546

4.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

5.  Pre-computed system matrix calculation based on a piece-wise method for PET.

Authors:  Abdella M Ahmed; Yohei Kikuchi; Shigeo Matsuyama; Atsuki Terakawa; Sodai Takyu; Hiroyuki Sugai; Keizo Ishii
Journal:  Radiol Phys Technol       Date:  2014-09-26

6.  Representing logic gates over Euclidean space via heaviside step function.

Authors:  Giovanni Iacovelli; Claudio Iacovelli
Journal:  Sci Rep       Date:  2022-05-14       Impact factor: 4.379

7.  Rotate-and-slant projector for fast LOR-based fully-3-D iterative PET reconstruction.

Authors:  Dan J Kadrmas
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

8.  A theoretical model for EM-ML reconstruction algorithms applied to rotating PET scanners.

Authors:  A Iriarte; C O S Sorzano; J M Carazo; J L Rubio; R Marabini
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

9.  MR-based PET motion correction procedure for simultaneous MR-PET neuroimaging of human brain.

Authors:  Marcus Görge Ullisch; Jürgen Johann Scheins; Christoph Weirich; Elena Rota Kops; Abdullah Celik; Lutz Tellmann; Tony Stöcker; Hans Herzog; Nadim Jon Shah
Journal:  PLoS One       Date:  2012-11-12       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.