Literature DB >> 17021423

The value of registration correction in the attenuation correction of myocardial SPECT studies using low resolution computed tomography images.

Christine M Tonge1, Gordon Ellul, Manish Pandit, Richard S Lawson, Robert A Shields, Parthiban Arumugam, Mary C Prescott.   

Abstract

BACKGROUND: Artifacts caused by tissue attenuation create problems in the interpretation of myocardial perfusion studies. In a previous study we evaluated attenuation correction using 'Hawkeye' and noted that the incidence of anterior/apical defects increased after attenuation correction. This increased incidence appeared to be associated with mis-registration between emission and transmission images. The main aim of this study was to determine whether correction of mis-registration between emission and transmission scans reduced the incidence of these anterior/apical defects.
METHODS: Ninety-four patients (64 men, 30 women) underwent stress/rest myocardial perfusion imaging using (99m)Tc-tetrofosmin (188 studies). Bull's-eye perfusion plots were created using proprietary software (QPS).
RESULTS: The marked reduction in defect size, particularly obvious in male patients, in the inferior wall after attenuation correction was not significantly changed by the addition of registration correction. In the anterior and apical walls attenuation correction produced a confusing pattern particularly in females with an overall tendency to increase the defect size. After registration correction fewer anterior/apical defects were created.
CONCLUSION: Attenuation correction using 'Hawkeye' reduces the incidence of inferior myocardial perfusion defects but can create anterior and/or apical artifacts. It is essential to evaluate registration carefully in three dimensions before reporting the images. Correction of mis-registration reduces the incidence of anterior/apical defects and can restore the appearance of the anterior/apical area to pre-correction levels.

Entities:  

Mesh:

Year:  2006        PMID: 17021423     DOI: 10.1097/01.mnm.0000239483.69027.23

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

Review 1.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

2.  Influence of CT-based attenuation correction in assessment of left and right ventricular functions with count-based gated blood-pool SPECT.

Authors:  Louis Sibille; Fayçal Ben Bouallegue; Aurélie Bourdon; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2011-06-07       Impact factor: 5.952

3.  CT-based attenuation correction in Tl-201 myocardial perfusion scintigraphy is less effective than non-corrected SPECT for risk stratification.

Authors:  Christos A Savvopoulos; Trifon Spyridonidis; Nikolaos Papandrianos; Pavlos J Vassilakos; Dimitrios Alexopoulos; Dimitris J Apostolopoulos
Journal:  J Nucl Cardiol       Date:  2014-02-15       Impact factor: 5.952

4.  Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images.

Authors:  Chao Wu; Hugo A Gratama van Andel; Peter Laverman; Otto C Boerman; Freek J Beekman
Journal:  EJNMMI Res       Date:  2013-01-31       Impact factor: 3.138

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.