Literature DB >> 17021422

Efficacy of milk versus water to reduce interfering infra-cardiac activity in 99mTc-sestamibi myocardial perfusion scintigraphy.

Michael Hofman1, John McKay, Dee Nandurkar.   

Abstract

OBJECTIVE: Interference from infra-cardiac radionuclide activity prevents accurate interpretation of true myocardial perfusion. The study aim was to compare the efficacy of milk versus water in reducing infra-cardiac activity in myocardial perfusion scintigraphy.
METHODS: We prospectively randomized 198 patients undergoing stress-rest (99m)Tc-sestamibi SPECT with exercise or pharmacological stress to drink 300 ml of water or milk prior to imaging. A semi-quantitative grading of the relative intensity of infra-cardiac activity compared to the myocardial activity and a qualitative assessment of the effect on the overall interpretation was performed.
RESULTS: For stress images, there was no infra-cardiac activity in 37.9%, less intense infra-cardiac activity in 40.8%, equal in 11.7% and greater than infra-cardiac activity in 9.7% with milk, compared with 20.0%, 49.5%, 20.0% and 10.5%, respectively, with water (P=0.038). For rest images, there was also less intense infra-cardiac activity with milk compared to water (P=0.014). However, no change in subsequent image interpretation was seen.
CONCLUSION: Administration of milk resulted in a significant decrease in the intensity of infra-cardiac activity compared to water. However, this did not translate into an improvement in image interpretation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17021422     DOI: 10.1097/01.mnm.0000237989.60196.71

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  5 in total

1.  Reduction of infracardiac intestinal activity by a small amount of soda water in technetium-99m tetrofosmin myocardial perfusion scintigraphy with adenosine stress.

Authors:  Masatake Hara; Hajime Monzen; Rie Futai; Koichi Inagaki; Hisashi Shimoyama; Masaru Morikawa; Nobuyoshi Tomioka; Takashi Konishi; Yutaka Watanabe; Rumio Yuki; Hisato Kobayashi; Kunihiko Hirose
Journal:  J Nucl Cardiol       Date:  2008-03-06       Impact factor: 5.952

2.  Feasibility of a rapid protocol of 1-day single-isotope rest/adenosine stress Tc-99m sestamibi ECG-gated myocardial perfusion imaging.

Authors:  Futoshi Tadehara; Hideya Yamamoto; Shuji Tsujiyama; Toshihide Hinoi; Shusuke Matsuo; Naoya Matsumoto; Yuichi Sato; Nobuoki Kohno
Journal:  J Nucl Cardiol       Date:  2008 Jan-Feb       Impact factor: 5.952

3.  The problem of radiotracer abdominal activity in myocardial perfusion imaging studies.

Authors:  Randall C Thompson
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 3.872

4.  Efficacy of full-fat milk and diluted lemon juice in reducing infra-cardiac activity of (99m)Tc sestamibi during myocardial perfusion imaging.

Authors:  Khushica Purbhoo; Mboyo Di Tamba Willy Vangu
Journal:  Cardiovasc J Afr       Date:  2015 Jul-Aug       Impact factor: 1.167

5.  Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy.

Authors:  Daris Theerakulpisut; Chanisa Chotipanich
Journal:  World J Nucl Med       Date:  2016 May-Aug
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.