Literature DB >> 17019036

Resolution of axial shear strain elastography.

Arun Thitaikumar1, Raffaella Righetti, Thomas A Krouskop, Jonathan Ophir.   

Abstract

The technique of mapping the local axial component of the shear strain due to quasi-static axial compression is defined as axial shear strain elastography. In this paper, the spatial resolution of axial shear strain elastography is investigated through simulations, using an elastically stiff cylindrical lesion embedded in a homogeneously softer background. Resolution was defined as the smallest size of the inclusion for which the strain value at the inclusion/background interface was greater than the average of the axial shear strain values at the interface and inside the inclusion. The resolution was measured from the axial shear strain profile oriented at 45 degrees to the axis of beam propagation, due to the absence of axial shear strain along the normal directions. The effects of the ultrasound system parameters such as bandwidth, beamwidth and transducer element pitch along with signal processing parameters such as correlation window length (W) and axial shift (DeltaW) on the estimated resolution were investigated. The results show that the resolution (at 45 degrees orientation) is determined by the bandwidth and the beamwidth. However, the upper bound on the resolution is limited by the larger of the beamwidth and the window length, which is scaled inversely to the bandwidth. The results also show that the resolution is proportional to the pitch and not significantly affected by the axial window shift.

Mesh:

Year:  2006        PMID: 17019036     DOI: 10.1088/0031-9155/51/20/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Elastography: modality-specific approaches, clinical applications, and research horizons.

Authors:  Yufei Li; Jess G Snedeker
Journal:  Skeletal Radiol       Date:  2010-03-30       Impact factor: 2.199

2.  Real-time quasi-static ultrasound elastography.

Authors:  Graham Treece; Joel Lindop; Lujie Chen; James Housden; Richard Prager; Andrew Gee
Journal:  Interface Focus       Date:  2011-04-20       Impact factor: 3.906

3.  On the advantages of imaging the axial-shear strain component of the total shear strain in breast tumors.

Authors:  Arun K Thittai; Belfor Galaz; Jonathan Ophir
Journal:  Ultrasound Med Biol       Date:  2012-09-10       Impact factor: 2.998

Review 4.  Optical coherence elastography for tissue characterization: a review.

Authors:  Shang Wang; Kirill V Larin
Journal:  J Biophotonics       Date:  2014-11-20       Impact factor: 3.207

5.  Nonlinear characterization of breast cancer using multi-compression 3D ultrasound elastography in vivo.

Authors:  Ahmed Sayed; Ginger Layne; Jame Abraham; Osama Mukdadi
Journal:  Ultrasonics       Date:  2013-01-23       Impact factor: 2.890

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.