Literature DB >> 17019035

Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning.

Shinichiro Mori1, Masahiro Endo, Hiroshi Asakura.   

Abstract

Respiratory-gated CT (RGCT) and four-dimensional CT (4DCT) scan techniques cover consecutive segments of the respiratory cycle. However, motion artefacts may occur in fast respiratory phases such as mid-inhalation and -exhalation. CT imaging involves the use of a number of x-ray tube positions for each couch position. We investigated the fundamental nature of motion artefacts using a constant-velocity moving phantom in motion in the CT plane or perpendicular to the CT plane, and in pigs to simulate a human model. Artefacts and movement distance were evaluated in a moving phantom and artificially ventilated pigs with a 256-multi-detector row CT (256MDCT). The phantom moved in the CT plane or perpendicular to the CT plane with a constant velocity. Backprojection used variable initial backprojection angles (IBAs). The phantom length for motion perpendicular to the CT plane was independent of IBA but was represented by phantom diameter plus the distance of movement per gantry rotation. In contrast, that for the motion in the CT plane was dependent on IBA, as represented by phantom diameter plus the distance of movement per rotation for IBA perpendicular to the phantom movement direction, and phantom diameter plus half the distance of movement per gantry rotation for other IBAs. Results for volumetric CT images with different IBAs showed the presence of banding artefacts. Similar findings were seen in artificially ventilated pigs. Motion artefacts are unavoidable in both conventional CT and 256MDCT. Banding artefacts will be improved if the same IBAs at each couch position are accounted for during image reconstruction. This improvement will be beneficial in respiratory gated and 4D radiation therapies.

Entities:  

Mesh:

Year:  2006        PMID: 17019035     DOI: 10.1088/0031-9155/51/20/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model.

Authors:  Shian-Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kimberly K Amrami; Richard A Berger; Cynthia H McCollough
Journal:  Skeletal Radiol       Date:  2007-09-06       Impact factor: 2.199

2.  Evaluation of Coronary Artery Disease in Patients with Atrial Fibrillation by Cardiac Computed Tomography for Catheter Ablation: CADAF-CT Trial 2.

Authors:  Yoshibumi Antoku; Masao Takemoto; Takahiro Mito; Akihiro Masumoto; Masatsugu Nozoe; Atsushi Tanaka; Yusuke Yamamoto; Takafumi Ueno; Takuya Tsuchihashi
Journal:  Intern Med       Date:  2020-07-21       Impact factor: 1.271

3.  Evaluation of coronary artery disease in patients with atrial fibrillation by cardiac computed tomography for catheter ablation: CADAF-CT trial.

Authors:  Takahiro Mito; Masao Takemoto; Yoshibumi Antoku; Akihiro Masumoto; Masatsugu Nozoe; Satoko Kinoshita; Atsushi Tanaka; Yusuke Yamamoto; Takafumi Ueno; Takuya Tsuchihashi
Journal:  Heart Vessels       Date:  2020-03-05       Impact factor: 2.037

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.