Literature DB >> 17015605

Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques.

Sara L Edwards1, Nicole A Wilson, Li-Qun Zhang, Steven Flores, Bradley R Merk.   

Abstract

BACKGROUND: Successful internal fixation of fractures of the surgical neck of the humerus can be difficult to achieve because of osteopenia of the proximal aspect of the humerus. The purpose of this study was to compare the biomechanical stability of a proximal humeral intramedullary nail and a locking plate for the treatment of a comminuted two-part fracture of the surgical neck in a human cadaver model.
METHODS: Twenty-four cadaveric humeri were instrumented with use of either a titanium proximal humeral nail (PHN) or a 3.5-mm locking compression plate for the proximal part of the humerus (LCP-PH). The specimens were matched by bone mineral density and were separated into four experimental groups with six humeri in each: PHN bending, LCP-PH bending, PHN torsion, or LCP-PH torsion. Comminuted fractures of the surgical neck were simulated by excising a 10-mm wedge of bone. Bending specimens were cyclically loaded from 0 to 7.5 Nm of varus bending moment at the fracture site. Torsion specimens were cyclically loaded to +/-2 Nm of axial torque. The mean and maximum displacement in bending, mean and maximum angular rotation in torsion, and stiffness of the bone-implant constructs were compared.
RESULTS: In bending, the LCP-PH group demonstrated significantly less mean displacement of the distal fragment than did the PHN group over 5000 cycles (p = 0.002). In torsion, the LCP-PH group demonstrated significantly less mean angular rotation than did the PHN group over 5000 cycles (p = 0.04). A significant number of specimens in the PHN group failed prior to reaching 5000 cycles (p = 0.04). The LCP-PH implant created a significantly stiffer bone-implant construct than did the PHN implant (p = 0.007).
CONCLUSIONS: The LCP proximal humeral plate demonstrated superior biomechanical characteristics compared with the proximal humeral nail when tested cyclically in both cantilevered varus bending and torsion. The rate of early failure of the proximal humeral nail could reflect the high moment transmitted to the locking proximal screw-bone interface in this implant. CLINICAL RELEVANCE: The high failure rate in torsion of the proximal humeral nail-bone construct is concerning, and, with relatively osteoporotic bone and early motion, the results could be poor.

Entities:  

Mesh:

Year:  2006        PMID: 17015605     DOI: 10.2106/JBJS.E.00757

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  32 in total

1.  [Biomechanical investigation on refixation of tuberosities on shoulder prostheses. Does refixation with different suture materials offer enough stability?].

Authors:  J Fleischer; A Schleyer; R Nassutt; H Grundei; U Grittner; S J Hopp
Journal:  Unfallchirurg       Date:  2010-08       Impact factor: 1.000

Review 2.  Fixed angle locking plates for proximal humeral fracture fixation.

Authors:  S Sinha; C P Kelly
Journal:  Ann R Coll Surg Engl       Date:  2010-11       Impact factor: 1.891

Review 3.  Management of proximal humerus fractures in adults.

Authors:  Leonidas Vachtsevanos; Lydia Hayden; Aravind S Desai; Asterios Dramis
Journal:  World J Orthop       Date:  2014-11-18

4.  Locked antegrade intramedullary nailing of humeral shaft fractures.

Authors:  C Iacobellis; T Agrò; R Aldegheri
Journal:  Musculoskelet Surg       Date:  2011-09-16

5.  Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.

Authors:  Ben Ockert; Vera Pedersen; Lucas Geyer; Stefan Wirth; Wolf Mutschler; Stefan Grote
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

6.  Treatment for proximal humeral fractures with percutaneous plating: our first results.

Authors:  D Imarisio; A Trecci; L Sabatini; R Scagnelli
Journal:  Musculoskelet Surg       Date:  2013-04-16

7.  Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens.

Authors:  Christine Voigt; Christof Hurschler; Louise Rechi; Rolf Vosshenrich; Helmut Lill
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

8.  [Effect of additive fiber cerclage of the rotator cuff in angle-stable plate-stabilized proximal humeral fractures: a biomechanical study of human shoulder specimens].

Authors:  C Voigt; C Hurschler; J Althainz; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

9.  PHN for treatment of proximal humerus fractures: evaluation of 80 cases.

Authors:  Claudio Iacobellis; Damiano Serafini; Roberto Aldegheri
Journal:  Chir Organi Mov       Date:  2009-05-26

10.  Proximal humeral fractures: an understanding of the ideal plate positioning.

Authors:  Pedro José Labronici; Rodrigo Pires e Albuquerque; Vinícius Schott; Robinson Esteves Santos Pires; Willian Dias Belangero; José Sérgio Franco
Journal:  Int Orthop       Date:  2014-07-20       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.