Literature DB >> 17004087

Indication for the need of flexible and frequency specific mapping functions in cochlear implant speech processors.

Sebastian Hoth1.   

Abstract

Categorical loudness scaling of electric and acoustic stimuli was performed in cochlear implant (CI) recipients equipped with Nucleus systems in order to achieve a normal loudness perception in the whole dynamic range of acoustic input. For each electrode, the lower and upper limits of electric stimulus were defined by the values corresponding to "very soft" and "too loud". Within this dynamic range, the stimulus strength intervals associated to the verbal categories "soft", "medium", "loud" and "very loud" were determined. The same loudness categories were used for the scaling of acoustic stimuli. From both scaling experiments, the transduction of the CI system can be assessed and the parameters of the individual mapping function yielding a normal loudness growth can be derived. Deviations from optimum mapping can be corrected at least partially by manipulating the parameters of the mapping function. In many cases, however, one mapping function is not sufficient for all channels. The results argue in favour of the development of flexible and channel-specific mapping function parameters in future CI systems.

Mesh:

Year:  2006        PMID: 17004087     DOI: 10.1007/s00405-006-0159-y

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  23 in total

1.  Effects of dynamic range and amplitude mapping on phoneme recognition in Nucleus-22 cochlear implant users.

Authors:  Q J Fu; R V Shannon
Journal:  Ear Hear       Date:  2000-06       Impact factor: 3.570

2.  Effects of amplitude compression on first- and second-order modulation detection thresholds in cochlear implant listeners.

Authors:  Christian Lorenzi; Jérome Sibellas; Christian Füllgrabe; Stéphane Gallégo; Claude Fugain; Bernard Meyer
Journal:  Int J Audiol       Date:  2004-05       Impact factor: 2.117

3.  [The Würzburg auditory field, a test for prosthetic audiometry].

Authors:  L M Moser
Journal:  HNO       Date:  1987-08       Impact factor: 1.284

4.  Electrical stimulation of the cochlea in man: hearing induction and tinnitus suppression.

Authors:  Y Cazals; M Negrevergne; J M Aran
Journal:  J Am Audiol Soc       Date:  1978 Mar-Apr

5.  A multi-channel hearing prosthesis for profound-to-total hearing loss.

Authors:  G M Clark; Y C Tong; J F Patrick; P M Seligman; P A Crosby; J A Kuzma; D K Money
Journal:  J Med Eng Technol       Date:  1984 Jan-Feb

6.  A multiple-electrode cochlear implant.

Authors:  W F House; B J Edgerton
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1982 Mar-Apr

7.  Growth of loudness for sinusoidal and pulsatile electrical stimulation.

Authors:  R V Shannon
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1981 Mar-Apr

8.  [Category loudness scaling to evaluate sound perception in cochlear and retro-cochlear lesions].

Authors:  M Nieschalk; F Schmäl; K W Delank; W Stoll
Journal:  HNO       Date:  1999-09       Impact factor: 1.284

9.  Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics.

Authors:  R V Shannon
Journal:  Hear Res       Date:  1983-08       Impact factor: 3.208

10.  [Loudness scaling. A procedure for quantitative recruitment detection].

Authors:  J Kiessling; M Schubert; I Wagner
Journal:  HNO       Date:  1994-06       Impact factor: 1.284

View more
  3 in total

Review 1.  [Audiologic rehabilitation of patients with cochlear implants].

Authors:  S Hoth; J Müller-Deile
Journal:  HNO       Date:  2009-07       Impact factor: 1.284

2.  Nasalance in Cochlear Implantees.

Authors:  Swapna Sebastian; N Sreedevi; Anjali Lepcha; John Mathew
Journal:  Clin Exp Otorhinolaryngol       Date:  2015-08-13       Impact factor: 3.372

3.  Real-time loudness normalisation with combined cochlear implant and hearing aid stimulation.

Authors:  Dimitar Spirrov; Maaike Van Eeckhoutte; Lieselot Van Deun; Tom Francart
Journal:  PLoS One       Date:  2018-04-04       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.