| Literature DB >> 17003852 |
Timothy Sangster1, Hilary Major, Robert Plumb, Amy J Wilson, Ian D Wilson.
Abstract
Metabonomic/metabolomic studies can involve the analysis of large numbers of samples for the detection of biomarkers and confidence in the analytical data, generated by methods such as GC and HPLC-MS, requires active measures on the part of the analyst. However, quality control for complex multi-component samples such as biofluids, where many of the components of interest in the sample are unknown prior to analysis, poses significant problems. Here the repeat analysis of a pooled sample throughout the run, thereby enabling the analysis to be monitored and controlled using targeted inspection of the data and pattern recognition, is advocated as a pragmatic solution to this problem.Mesh:
Substances:
Year: 2006 PMID: 17003852 DOI: 10.1039/b604498k
Source DB: PubMed Journal: Analyst ISSN: 0003-2654 Impact factor: 4.616