The effect of prosthesis alignment on the symmetry of gait in subjects with unilateral transtibial amputation.

Daniel H K Chow1, Andrew D Holmes, Christina K L Lee, S W Sin.   

Abstract

A high degree of gait symmetry is characteristic of healthy gait. The aim of this study is to examine the symmetry of various gait parameters in subjects with unilateral trans-tibial amputation over a range of acceptable anteroposterior translational and tilt alignments, and further to examine if a consistent alignment of highest symmetry can be found. Acceptable alignments were determined by bench, static and dynamic testing on level and non-level surfaces. A total of 15 kinetic and kinematic parameters were then measured in the seven subjects participating in this study. Results indicate that some parameters show consistently higher symmetries, particularly the vertical ground reaction force parameters and the stance duration, step length and time to full knee flexion during the swing phase. Symmetries in other parameters such as knee flexion at loading response, acceleration impulse, and peak anteroposterior propulsive force seem to have little relevance in determining whether the gait pattern for that prosthetic alignment is acceptable or not. While analysis of the symmetry of more relevant gait parameters may assist the prosthetist in consistently and objectively identifying a most symmetrical alignment within the acceptable range, further clinical study is required before any conclusions can be drawn regarding evaluation of symmetry as a tool in defining any optimum alignment.

Mesh:

Year:  2006        PMID: 16990222     DOI: 10.1080/03093640600568617

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  10 in total

1.  Criterion and construct validity of prosthesis-integrated measurement of joint moment data in persons with transtibial amputation.

Authors:  Goeran Fiedler; Brooke Slavens; Roger O Smith; Douglas Briggs; Brian J Hafner
Journal:  J Appl Biomech       Date:  2014-03-04       Impact factor: 1.833

2.  Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

Authors:  Toshiki Kobayashi; Adam K Arabian; Michael S Orendurff; Teri G Rosenbaum-Chou; David A Boone
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-13       Impact factor: 2.063

3.  Effects of physical exertion on trans-tibial prosthesis users' ability to accommodate alignment perturbations.

Authors:  Goeran Fiedler; Brooke A Slavens; Kristian M O'Connor; Roger O Smith; Brian J Hafner
Journal:  Prosthet Orthot Int       Date:  2014-08-19       Impact factor: 1.895

4.  Kinetic Gait Parameters in Unilateral Lower Limb Amputations and Normal Gait in Able-Bodied: Reference Values for Clinical Application.

Authors:  Karin Schmid-Zalaudek; Theresa Fischer; Zoltán Száva; Helmut Karl Lackner; Ursula Kropiunig; Christian Bittner; Karl Höcker; Günther Winkler; Gerfried Peternell
Journal:  J Clin Med       Date:  2022-05-10       Impact factor: 4.964

5.  Textile-based Pressure Sensors for Monitoring Prosthetic-Socket Interfaces.

Authors:  Jordan Tabor; Talha Agcayazi; Aaron Fleming; Brendan Thompson; Ashish Kapoor; Ming Liu; Michael Lee; He Helen Huang; Alper Bozkurt; Tushar Ghosh
Journal:  IEEE Sens J       Date:  2021-01-21       Impact factor: 3.301

Review 6.  The Effect of Alignment Changes on Unilateral Transtibial Amputee's Gait: A Systematic Review.

Authors:  Niels Jonkergouw; Maarten R Prins; Arjan W P Buis; Peter van der Wurff
Journal:  PLoS One       Date:  2016-12-06       Impact factor: 3.240

7.  Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking.

Authors:  Veerle Creylman; Ingrid Knippels; Paul Janssen; Evelyne Biesbrouck; Knut Lechler; Louis Peeraer
Journal:  Biomed Eng Online       Date:  2016-12-19       Impact factor: 2.819

Review 8.  Effectiveness of treadmill training on gait function in children with cerebral palsy: meta-analysis.

Authors:  Yong-Gu Han; Chang-Kyo Yun
Journal:  J Exerc Rehabil       Date:  2020-02-26

9.  The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali
Journal:  PLoS One       Date:  2014-05-14       Impact factor: 3.240

10.  Patient-Preferred Prosthetic Ankle-Foot Alignment for Ramps and Level-Ground Walking.

Authors:  Max K Shepherd; Ann M Simon; Joey Zisk; Levi J Hargrove
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2021-02-25       Impact factor: 3.802