Literature DB >> 16988597

Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer.

Felipe A Medeiros1, Robert N Weinreb.   

Abstract

PURPOSE: The Ocular Response Analyzer (ORA) proposes to measure corneal biomechanical properties in vivo by monitoring and analyzing the corneal behavior when this structure is submitted to a force induced by an air jet. The purpose of this study was to evaluate the relationship between corneal biomechanical properties and corneal-compensated intraocular pressure (IOPCC) measurements as obtained by the ORA and Goldmann applanation tonometry (GAT) measurements.
DESIGN: Observational clinical study.
METHODS: The study included 153 eyes of 78 subjects. All subjects underwent IOP evaluation with the ORA and GAT, and also measurements of central corneal thickness (CCT), corneal curvature, and axial length. Univariable and multivariable regression analysis were used to evaluate the associations between IOP (as measured with GAT and ORA) and CCT, corneal curvature, axial length, and age. Bland and Altman plots were used to evaluate the agreement between IOP measurements obtained by GAT and ORA.
RESULTS: GAT IOP measurements were significantly associated with CCT (P=0.001) and corneal curvature (P<0.001), whereas ORA IOPCC measurements were not associated with any of the ocular variables. The difference between GAT and IOPCC measurements was significantly influenced by corneal thickness. Patients with thicker corneas tended to have higher GAT IOP measurements compared with IOPCC, whereas in patients with thin corneas, GAT IOP measurements tended to be lower than IOPCC.
CONCLUSIONS: ORA IOPCC measurements seem to provide an estimate of IOP that is less influenced by corneal properties than those provided by GAT.

Entities:  

Mesh:

Year:  2006        PMID: 16988597     DOI: 10.1097/01.ijg.0000212268.42606.97

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  78 in total

1.  Comparison of corneal biomechanical properties between healthy blacks and whites using the Ocular Response Analyzer.

Authors:  Mauro T Leite; Luciana M Alencar; Charlotte Gore; Robert N Weinreb; Pamela A Sample; Linda M Zangwill; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2010-06-11       Impact factor: 5.258

2.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

Authors:  Joo Young Shin; Jin Seok Choi; Joo Youn Oh; Mee Kum Kim; Jin Hak Lee; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2010-06-05

3.  Mechanical interferometry imaging for creep modeling of the cornea.

Authors:  Lawrence Yoo; Jason Reed; James K Gimzewski; Joseph L Demer
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-28       Impact factor: 4.799

4.  Association between corneal biomechanical properties and glaucoma severity.

Authors:  Kaweh Mansouri; Mauro T Leite; Robert N Weinreb; Ali Tafreshi; Linda M Zangwill; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2011-10-21       Impact factor: 5.258

5.  Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma.

Authors:  Tetsuya Morita; Nobuyuki Shoji; Kazutaka Kamiya; Mana Hagishima; Fusako Fujimura; Kimiya Shimizu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-08-20       Impact factor: 3.117

6.  Effect of pathological myopia on biomechanical properties: a study by ocular response analyzer.

Authors:  Veysi Öner; Mehmet Taş; Erdal Özkaya; Yavuz Oruç
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

7.  Comparative analysis of biomechanically corrected intraocular pressure with corneal visualization Scheimpflug technology versus conventional noncontact intraocular pressure.

Authors:  Jiaonan Ma; Yan Wang; Weiting Hao; Vishal Jhanji
Journal:  Int Ophthalmol       Date:  2019-08-20       Impact factor: 2.031

8.  Impact of corneal parameters on intraocular pressure measurements in different tonometry methods.

Authors:  Aleksandra Zakrzewska; Marta P Wiącek; Anna Machalińska
Journal:  Int J Ophthalmol       Date:  2019-12-18       Impact factor: 1.779

9.  Comparison among Ocular Response Analyzer, Corvis ST and Goldmann applanation tonometry in healthy children.

Authors:  Ramin Salouti; Ali Agha Alishiri; Reza Gharebaghi; Mostafa Naderi; Khosrow Jadidi; Ahmad Shojaei-Baghini; Mohammadreza Talebnejad; Zahra Nasiri; Seyedmorteza Hosseini; Fatemeh Heidary
Journal:  Int J Ophthalmol       Date:  2018-08-18       Impact factor: 1.779

10.  Intraocular pressure profile during the modified diurnal tension curve using Goldman applanation tonometry and dynamic contour tonometry.

Authors:  Carlos Gustavo Vasconcelos de Moraes; Alexandre Soares Castro Reis; Milena Eimi Sano; Alan Kardec Barreira; Roberto Murad Vessani; Remo Jr Susanna
Journal:  J Ocul Biol Dis Infor       Date:  2009-02-24
View more