Literature DB >> 16987913

Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F fluorodeoxyglucose (FDG).

T Seierstad1, E Stranden, K Bjering, M Evensen, A Holt, H M Michalsen, O Wetteland.   

Abstract

The first dedicated PET/CT centre in Norway was established at the Norwegian Radiumhospital in Oslo in 2005. Knowing that the introductions of PET-isotopes in nuclear medicine give increased occupational radiation dose to the technicians, a study was carried out in order to map the doses to staff members during different working operations and to see if any dose reducing measures were needed. The results of the study are in good agreement with other studies, and a technician dose of 20-25 nSv per injected MBq of 18F seems to be representative for such centres. For an average injected activity of 350 MBq per patient, the dose limit is reached after handling around 3000 patients annually. For an annual number of less than 500 patients at the centre and rotation of the staff, an annual individual dose for the technicians would realistically be less than 2-3 mSv. Even a major increase in the number of patients will not result in individual doses near the ICRP dose limit.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16987913     DOI: 10.1093/rpd/ncl141

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

1.  Validation of a new protocol for ¹⁸F-FDG infusion using an automatic combined dispenser and injector system.

Authors:  Michela Lecchi; Giovanni Lucignani; Claudio Maioli; Giuseppe Ignelzi; Angelo Del Sole
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-06-28       Impact factor: 9.236

2.  Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures.

Authors:  Stephen P Povoski; Ismet Sarikaya; William C White; Steven G Marsh; Nathan C Hall; George H Hinkle; Edward W Martin; Michael V Knopp
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07-10       Impact factor: 9.236

3.  Effective and equivalent dose minimization for personnel in PET procedures: how far are we from the goal?

Authors:  M Lecchi; S Malaspina; A Del Sole
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-12       Impact factor: 9.236

Review 4.  Joint EANM/SNMMI/ESTRO practice recommendations for the use of 2-[18F]FDG PET/CT external beam radiation treatment planning in lung cancer V1.0.

Authors:  Sofia C Vaz; Judit A Adam; Roberto C Delgado Bolton; Pierre Vera; Wouter van Elmpt; Ken Herrmann; Rodney J Hicks; Yolande Lievens; Andrea Santos; Heiko Schöder; Bernard Dubray; Dimitris Visvikis; Esther G C Troost; Lioe-Fee de Geus-Oei
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-01-13       Impact factor: 10.057

5.  Gene expression signatures of radiation response are specific, durable and accurate in mice and humans.

Authors:  Sarah K Meadows; Holly K Dressman; Garrett G Muramoto; Heather Himburg; Alice Salter; ZhengZheng Wei; Geoffrey S Ginsburg; Geoff Ginsburg; Nelson J Chao; Joseph R Nevins; John P Chute
Journal:  PLoS One       Date:  2008-04-02       Impact factor: 3.240

6.  Radiation Exposure to the Personnel Performing Robotic Arm-Assisted Positron Emission Tomography/Computed Tomography-Guided Biopsies.

Authors:  Tamanna Lakhanpal; Bhagwant Rai Mittal; Rajender Kumar; Ankit Watts; Nivedita Rana; Harmandeep Singh
Journal:  Indian J Nucl Med       Date:  2018 Jul-Sep
  6 in total