Literature DB >> 16987335

Agreement between PiCCO pulse-contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off-pump coronary artery by-pass surgery.

P S Halvorsen1, A Espinoza, R Lundblad, M Cvancarova, P K Hol, E Fosse, T I Tønnessen.   

Abstract

BACKGROUND: Haemodynamic instability during off-pump coronary artery bypass surgery (OPCAB) may appear rapidly, and continuous monitoring of the cardiac index (CI) during the procedure is advisable. With the PiCCO monitor, CI can be measured continuously and almost real time with pulse-contour analysis and intermittently with transthoracic thermodilution. The agreement between pulmonal artery thermodilution CI (Tpa), transthoracic thermodilution CI (Tpc) and pulse-contour CI (PCCI) during OPCAB surgery has not been evaluated sufficiently.
METHODS: In 30 patients scheduled for OPCAB surgery, a pulmonary artery catheter and a PiCCO catheter were inserted. At different time points during surgery, Tpa, Tpc and PCCI were compared. Measurements were performed after induction of anesthesia (T1), after pericardiothomy (T2), after grafting on the anterior (T3), posterior (T4) and lateral (T5) walls and after chest closure (T6). The PCCI was recalibrated at time point T2-T6.
RESULTS: Mean difference and the limits of agreements (percentage error) between Tpa and Tpc were: -0.14 +/- 0.60 (22.0%) l/min/m2, between Tpa and PCCI: -0.07 +/- 0.92 (33.5%) l/min/m2 and between Tpc and PCCI: 0.10 +/- 1.00 (35.5%) l/min/m2. For changes in CI from one time point to the next (DeltaCI), the limits of agreements between DeltaCI Tpa and DeltaCI Tpc were 0.04 +/- 0.90 l/min/m2, between DeltaCI Tpa and DeltaCI PCCI: -0.02 +/- 1.22 l/min/m2 and between DeltaCI Tpc and DeltaCI PCCI: -0.08 +/- 1.32 l/min/m2.
CONCLUSION: In OPCAB surgery, limits of agreement comparing thermodilution methods were smaller than comparing PCCI with thermodilution. Recalibration of PCCI is therefore advisable.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16987335     DOI: 10.1111/j.1399-6576.2006.01118.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  14 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

2.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

3.  Myths about critical care echocardiography: the ten false beliefs that intensivists should understand.

Authors:  Paul Mayo; Armand Mekontso Dessap; Armand Mekontso Dessap; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2015-01-10       Impact factor: 17.440

4.  Accuracy and precision of transcardiopulmonary thermodilution in patients with cardiogenic shock.

Authors:  Bonaventura Schmid; Katrin Fink; Manfred Olschewski; Stephan Richter; Tilmann Schwab; Michael Brunner; Hans-Joerg Busch
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

5.  Continuous arterial pressure waveform monitoring in pediatric cardiac transplant, cardiomyopathy and pulmonary hypertension patients.

Authors:  Sarena Teng; Jon Kaufman; Zhaoxing Pan; Angela Czaja; Heather Shockley; Eduardo da Cruz
Journal:  Intensive Care Med       Date:  2011-05-31       Impact factor: 17.440

6.  Clinical evaluation of the flotrac/Vigileo system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section: a pilot study.

Authors:  José Otavio Costa Auler; Marcelo L A Torres; Mônica M Cardoso; Thais C Tebaldi; André P Schmidt; Mario M Kondo; Marcelo Zugaib
Journal:  Clinics (Sao Paulo)       Date:  2010-06       Impact factor: 2.365

7.  Comparison of goal-directed hemodynamic optimization using pulmonary artery catheter and transpulmonary thermodilution in combined valve repair: a randomized clinical trial.

Authors:  Andrey I Lenkin; Mikhail Y Kirov; Vsevolod V Kuzkov; Konstantin V Paromov; Alexey A Smetkin; Mons Lie; Lars J Bjertnæs
Journal:  Crit Care Res Pract       Date:  2012-04-30

8.  The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function.

Authors:  Youn Yi Jo; Jong Wook Song; Young Chul Yoo; Ji Young Park; Jae Kwang Shim; Young Lan Kwak
Journal:  Korean J Anesthesiol       Date:  2011-04-26

9.  Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery.

Authors:  Ole Broch; Jochen Renner; Jan Höcker; Matthias Gruenewald; Patrick Meybohm; Jan Schöttler; Markus Steinfath; Berthold Bein
Journal:  Crit Care       Date:  2011-02-28       Impact factor: 9.097

10.  Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients.

Authors:  Alban Senn; Danny Button; Andreas Zollinger; Christoph K Hofer
Journal:  Crit Care       Date:  2009-03-04       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.