Literature DB >> 16985285

Radiation risk assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study.

T Makri1, E Yakoumakis, D Papadopoulou, G Gialousis, V Theodoropoulos, P Sandilos, E Georgiou.   

Abstract

Seeking to assess the radiation risk associated with radiological examinations in neonatal intensive care units, thermo-luminescence dosimetry was used for the measurement of entrance surface dose (ESD) in 44 AP chest and 28 AP combined chest-abdominal exposures of a sample of 60 neonates. The mean values of ESD were found to be equal to 44 +/- 16 microGy and 43 +/- 19 microGy, respectively. The MCNP-4C2 code with a mathematical phantom simulating a neonate and appropriate x-ray energy spectra were employed for the simulation of the AP chest and AP combined chest-abdominal exposures. Equivalent organ dose per unit ESD and energy imparted per unit ESD calculations are presented in tabular form. Combined with ESD measurements, these calculations yield an effective dose of 10.2 +/- 3.7 microSv, regardless of sex, and an imparted energy of 18.5 +/- 6.7 microJ for the chest radiograph. The corresponding results for the combined chest-abdominal examination are 14.7 +/- 7.6 microSv (males)/17.2 +/- 7.6 microSv (females) and 29.7 +/- 13.2 microJ. The calculated total risk per radiograph was low, ranging between 1.7 and 2.9 per million neonates, per film, and being slightly higher for females. Results of this study are in good agreement with previous studies, especially in view of the diversity met in the calculation methods.

Mesh:

Year:  2006        PMID: 16985285     DOI: 10.1088/0031-9155/51/19/019

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Quantification of scatter radiation from radiographic procedures in a neonatal intensive care unit.

Authors:  Mariaconcetta Longo; Elisabetta Genovese; Salvatore Donatiello; Bartolomeo Cassano; Teresa Insero; Mauro Campoleoni; Antonella Del Vecchio; Andrea Magistrelli; Paolo Tomà; Vittorio Cannatà
Journal:  Pediatr Radiol       Date:  2018-02-13

2.  Dose-Related Analysis in Percutaneous Central Venous Catheters Insertion: Experience of a Pediatric Interventional Radiology Center.

Authors:  Gian Luigi Natali; Giulia Cassanelli; Claudia Polito; Vittorio Cannatà; Marco Martinelli; Massimo Rollo
Journal:  Children (Basel)       Date:  2022-05-06

3.  Estimation of radiation dose and risk to children undergoing cardiac catheterization for the treatment of a congenital heart disease using Monte Carlo simulations.

Authors:  Emmanuel Yakoumakis; Helen Kostopoulou; Triantafilia Makri; Anastastios Dimitriadis; Evaggelos Georgiou; Ioannis Tsalafoutas
Journal:  Pediatr Radiol       Date:  2012-10-24

4.  Relative distribution of pertinent findings on portable neonatal abdominal radiographs: can we shield the gonads?

Authors:  Matthew Winfeld; Naomi Strubel; Lynne Pinkney; Shailee Lala; Sarah Milla; James Babb; Nancy Fefferman
Journal:  Pediatr Radiol       Date:  2013-05-02

5.  Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging.

Authors:  Tae-Hoon Kim; Dong-Woon Heo; Chang-Won Jeong; Jong-Hyun Ryu; Hong Young Jun; Seung-Jun Han; Taeuk Ha; Kwon-Ha Yoon
Journal:  Sensors (Basel)       Date:  2017-03-07       Impact factor: 3.576

6.  Investigation of patient dose from common radiology examinations in Isfahan, Iran.

Authors:  Daryoush Shahbazi-Gahrouei; Milad Baradaran-Ghahfarokhi
Journal:  Adv Biomed Res       Date:  2012-05-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.