Literature DB >> 16982564

Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results.

J J Nuyttens1, J-B Prévost, J Praag, M Hoogeman, R J Van Klaveren, P C Levendag, P M T Pattynama.   

Abstract

Lung tumor tracking during stereotactic radiotherapy with the CyberKnife requires the insertion of markers in or close to the tumor. To reduce the risk of pneumothorax, three methods of marker placement were used: 1) intravascular coil placement, 2) percutaneous intrathoracal, and 3) percutaneous extrathoracal placement. We investigated the toxicity of marker placement and the tumor response of the lung tumor tracking treatment. Markers were placed in 20 patients with 22 tumors: 13 patients received a curative treatment, seven a palliative. The median Charlson Comorbidity Score was 4 (range: 1-8). Platinum fiducials and intravascular embolisation coils were used as markers. In total, 78 markers were placed: 34 intrathoracal, 23 intravascular and 21 extrathoracal. The PTV equaled the GTV + 5 mm. A median dose of 45 Gy (range: 30-60 Gy, in 3 fractions) was prescribed to the 70-85% isodose. The response was evaluated with a CTscan performed 6-8 weeks after the last treatment and routinely thereafter. The median follow-up was 4 months (range: 2-11). No severe toxicity due to the marker placement was seen. Pneumothorax was not seen. The local control was 100%. Four tumors in four patients showed a complete response, 15 tumors in 14 patients a partial response, and three tumors in two patients with metastatic disease had stable disease. No severe toxicity of marker placement was seen due to the appropriate choice of one of the three methods. CyberKnife tumor tracking with markers is feasible and resulted in excellent tumor response. Longer follow-up is needed to validate the local control.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16982564     DOI: 10.1080/02841860600902205

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  28 in total

1.  Clinical outcome of fiducial-less CyberKnife radiosurgery for stage I non-small cell lung cancer.

Authors:  In-Hye Jung; Si Yeol Song; Jinhong Jung; Byungchul Cho; Jungwon Kwak; Hyoung Uk Je; Wonsik Choi; Nuri Hyun Jung; Su Ssan Kim; Eun Kyung Choi
Journal:  Radiat Oncol J       Date:  2015-06-30

2.  A novel phantom for characterization of dual energy imaging using an on-board imaging system.

Authors:  Maksat Haytmyradov; Rakesh Patel; Hassan Mostafavi; Murat Surucu; Adam Wang; Matthew M Harkenrider; John C Roeske
Journal:  Phys Med Biol       Date:  2019-01-21       Impact factor: 3.609

3.  Effect of secondary particles on image quality of dynamic flat panels in carbon ion scanning beam treatment.

Authors:  S Mori; S Amano; T Furukawa; T Shirai; K Noda
Journal:  Br J Radiol       Date:  2014-12-23       Impact factor: 3.039

4.  Evaluation of a template-based algorithm for markerless lung tumour localization on single- and dual-energy kilovoltage images.

Authors:  Alec M Block; Rakesh Patel; Murat Surucu; Matthew M Harkenrider; John C Roeske
Journal:  Br J Radiol       Date:  2016-10-12       Impact factor: 3.039

Review 5.  Technical advances in external radiotherapy for hepatocellular carcinoma.

Authors:  Shin-Hyung Park; Jae-Chul Kim; Min Kyu Kang
Journal:  World J Gastroenterol       Date:  2016-08-28       Impact factor: 5.742

6.  Robotic stereotactic body radiation therapy for elderly medically inoperable early-stage non-small cell lung cancer.

Authors:  Sana D Karam; Zachary D Horne; Robert L Hong; Nimrah Baig; Gregory J Gagnon; Don McRae; David Duhamel; Nadim M Nasr
Journal:  Lung Cancer (Auckl)       Date:  2013-08-06

Review 7.  Magnetic resonance imaging in precision radiation therapy for lung cancer.

Authors:  Hannah Bainbridge; Ahmed Salem; Rob H N Tijssen; Michael Dubec; Andreas Wetscherek; Corinne Van Es; Jose Belderbos; Corinne Faivre-Finn; Fiona McDonald
Journal:  Transl Lung Cancer Res       Date:  2017-12

Review 8.  Navigational transbronchial needle aspiration, percutaneous needle aspiration and its future.

Authors:  Sixto Arias; Lonny Yarmus; A Christine Argento
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

9.  Audiovisual biofeedback improves motion prediction accuracy.

Authors:  Sean Pollock; Danny Lee; Paul Keall; Taeho Kim
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

10.  Stereotactic body radiation therapy with or without transarterial chemoembolization for patients with primary hepatocellular carcinoma: preliminary analysis.

Authors:  Byung Ock Choi; Ihl Bohng Choi; Hong Seok Jang; Young Nam Kang; Ji Sun Jang; Si Hyun Bae; Seung Kew Yoon; Gyu Young Chai; Ki Mun Kang
Journal:  BMC Cancer       Date:  2008-11-27       Impact factor: 4.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.