Literature DB >> 16982558

Respiration correlated cone-beam computed tomography and 4DCT for evaluating target motion in Stereotactic Lung Radiation Therapy.

Thomas G Purdie1, Douglas J Moseley, Jean-Pierre Bissonnette, Michael B Sharpe, Kevin Franks, Andrea Bezjak, David A Jaffray.   

Abstract

An image-guidance process for using cone-beam computed tomography (CBCT) for stereotactic body radiation therapy (SBRT) of peripheral lung lesions is presented. Respiration correlated CBCT on the treatment unit and four dimensional computed tomography (4DCT) from planning are evaluated for assessing respiration-induced target motion during planning and treatment fractions. Image-guided SBRT was performed for 12 patients (13 lesions) with inoperable early stage non-small cell lung carcinoma. Kilovoltage (kV) projections were acquired over a 360 degree gantry rotation and sorted based on the pixel value of an image-based aperture located at the air-tissue interface of the diaphragm. The sorted projections were reconstructed to provide volumetric respiration correlated CBCT image datasets at different phases of the respiratory cycle. The 4D volumetric datasets were directly compared with 4DCT datasets acquired at the time of planning. For ten of 12 patients treated, the lung tumour motion, as measured by respiration correlated CBCT on the treatment unit, was consistent with the tumour motion measured by 4DCT at the time of planning. However, in two patients, maximum discrepancies observed were 6 and 10 mm in the anterior-posterior and superior-inferior directions, respectively. Respiration correlated CBCT acquired on the treatment unit allows target motion to be assessed for each treatment fraction, allows target localization based on different phases on the breathing cycle, and provides the facility for adaptive margin design in radiation therapy of lung malignancies. The current study has shown that the relative motion and position of the tumour at the time of treatment may not match that of the planning 4DCT scan. Therefore, application of breathing motion data acquired at simulation for tracking or gating radiation therapy may not be suitable for all patients - even those receiving short course treatment techniques such as SBRT.

Entities:  

Mesh:

Year:  2006        PMID: 16982558     DOI: 10.1080/02841860600907345

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  32 in total

1.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

4.  A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography.

Authors:  K S Kim; S Y Kang; C K Park; G A Kim; S Y Park; Hyosung Cho; C W Seo; D Y Lee; H W Lim; H W Lee; J E Park; T H Woo; J E Oh
Journal:  J Digit Imaging       Date:  2019-06       Impact factor: 4.056

5.  Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems.

Authors:  Stephen J Gardner; Matthew T Studenski; Tawfik Giaddui; Yunfeng Cui; James Galvin; Yan Yu; Ying Xiao
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

6.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

7.  Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables.

Authors:  Morten Nielsen; Christian R Hansen; Carsten Brink; Anders S Bertelsen; Charlotte Kristiansen; Jeppesen Stefan S; Olfred Hansen
Journal:  J Radiosurg SBRT       Date:  2016

8.  Potential underestimation of the internal target volume (ITV) from free-breathing CBCT.

Authors:  Irina Vergalasova; Jacqueline Maurer; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

9.  Measuring interfraction and intrafraction lung function changes during radiation therapy using four-dimensional cone beam CT ventilation imaging.

Authors:  John Kipritidis; Geoffrey Hugo; Elisabeth Weiss; Jeffrey Williamson; Paul J Keall
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

10.  A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer.

Authors:  J P Santoro; J McNamara; E Yorke; H Pham; A Rimner; K E Rosenzweig; G S Mageras
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.