Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors.

Matthias Guckenberger1, Juergen Meyer, Juergen Wilbert, Kurt Baier, Gerd Mueller, Joern Wulf, Michael Flentje.   

Abstract

Cone-beam CT (CB-CT) based image-guidance was evaluated for extracranial stereotactic radiotherapy of intrapulmonary tumors. A total of 21 patients (25 lesions: prim. NSCLC n = 6; pulmonary metastases n = 19) were treated with stereotactic radiotherapy (1 to 8 fractions). Prior to every fraction a CB-CT was acquired in treatment position, errors between planned and actual tumor position were measured and corrected. Intra- and inter-observer variability of manual evaluation of tumor position error was investigated and this manual method was compared with automatic image registration. Based on CB-CTs from 66 fractions the discrepancy (3-D vector) between planned and actual tumor position was 7.7 mm +/-1.3 mm. Tumor position error relative to the bony anatomy was 5.3 mm +/-1.2 mm, the correlation between bony anatomy and tumor position was poor. Intra-observer and inter-observer variability of manual evaluation of tumor position error was 0.9 mm +/-0.8 mm and 2.3 mm +/-1.1 mm, respectively. Automatic image registration showed highly reproducible results (<1 mm). However, compared with manual registration a systematic error was found in direction of predominant tumor breathing motion (2.5 mm vs 1.4 mm). Image-guidance using CB-CT was validated for high precision radiotherapy of intrapulmonary tumors. It was shown that both the planning reference and the verification image study have to consider tumor breathing motion.

Entities:  

Mesh:

Year:  2006        PMID: 16982556     DOI: 10.1080/02841860600904839

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  31 in total

1.  Localization accuracy of the clinical target volume during image-guided radiotherapy of lung cancer.

Authors:  Geoffrey D Hugo; Elisabeth Weiss; Ahmed Badawi; Matthew Orton
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-27       Impact factor: 7.038

2.  On the accuracy of isocenter verification with kV imaging in stereotactic radiosurgery.

Authors:  Rolf Wiehle; Hans-Jürgen Koth; Norbert Nanko; Anca-Ligia Grosu; Norbert Hodapp
Journal:  Strahlenther Onkol       Date:  2009-05-15       Impact factor: 3.621

Review 3.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

4.  Evaluation of Elekta 4D cone beam CT-based automatic image registration for radiation treatment of lung cancer.

Authors:  Jun Li; Amy Harrison; Yan Yu; Ying Xiao; Maria Werner-Wasik; Bo Lu
Journal:  Br J Radiol       Date:  2015-07-17       Impact factor: 3.039

Review 5.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

6.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

Review 7.  Stereotactic body radiotherapy: current strategies and future development.

Authors:  Maverick W K Tsang
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

8.  Interobserver variability of patient positioning using four different CT datasets for image registration in lung stereotactic body radiotherapy.

Authors:  Markus Oechsner; Barbara Chizzali; Michal Devecka; Stefan Münch; Stephanie Elisabeth Combs; Jan Jakob Wilkens; Marciana Nona Duma
Journal:  Strahlenther Onkol       Date:  2017-07-19       Impact factor: 3.621

9.  Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer.

Authors:  Hongbo Chai; Yuichiro Narita; Masafumi Takagi; Mikiko Kudo; Tomomi Kimura; Keiichi Kattou
Journal:  Radiol Phys Technol       Date:  2019-09-23

10.  Evolution of surface-based deformable image registration for adaptive radiotherapy of non-small cell lung cancer (NSCLC).

Authors:  Matthias Guckenberger; Kurt Baier; Anne Richter; Juergen Wilbert; Michael Flentje
Journal:  Radiat Oncol       Date:  2009-12-21       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.