Literature DB >> 16979795

The sensitivity of approved Ninhydrin and Biuret tests in the assessment of protein contamination on surgical steel as an aid to prevent iatrogenic prion transmission.

I P Lipscomb1, H E Pinchin, R Collin, K Harris, C W Keevil.   

Abstract

Regulations recommend the routine application of biochemical tests, such as the Ninhydrin or Biuret tests, to confirm the efficacy of hospital sterile service department (SSD) washer-disinfector cycles in removing proteinaceous material, particularly with respect to prions. The effectiveness of these methods relies on both the effective sampling of the instruments and the sensitivity of the tests employed. Two commercially available contamination assessment tests were evaluated for their sensitivity to ME7 brain homogenate on surgical-grade stainless steel surfaces. Controls were visualized by the application of episcopic differential interference contrast/Epi-fluorecence microscopy (EDIC/EF) combined with the sensitive fluorescent reagent, SYPRO Ruby, which has been shown previously to rapidly visualize and assess low levels of contamination on medical devices. The Ninhydrin test displayed a minimum level of detection observed by 75% of volunteers (MLD(75)) of 9.25 microg [95% confidence interval (95% CI) 8.6-10.0 microg]. The Biuret test provided better sensitivity, with a MLD(75) of 6.7 microg (95% CI 5.4-8.2 microg). However, much lower concentrations of proteinaceous soiling (pg) were visualized using the EDIC/EF microscopy method. From these findings, it is clear that these approved colorimetric tests of cleaning are relatively insensitive. This investigation demonstrates how large amounts (up to 6.5 microg) of proteinaceous brain contamination could remain undetected and the instruments deemed clean using such methods. The application of more sensitive cleanliness evaluation methods should be applied to reduce the risk of iatrogenic transmission of prion disease in 'high-risk' instruments such as neurosurgical devices.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16979795     DOI: 10.1016/j.jhin.2006.07.007

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  1 in total

1.  Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units.

Authors:  Gordon Wg Smith; Andrew J Smith; Frank Goldie; Steven Long; David F Lappin; Gordon Ramage
Journal:  J Foot Ankle Res       Date:  2011-01-10       Impact factor: 2.303

  1 in total