Literature DB >> 16977385

Effect of pH, temperature and Cl- concentration on electrochemical behavior of NiTi shape memory alloy in artificial saliva.

Jianqiu Wang1, Nianxing Li, En-hou Han, Wei Ke.   

Abstract

The cooperation of pH, temperature and Cl- concentration on electrochemical behavior of NiTi shape memory alloy in artificial saliva was studied using orthogonal test method. The results showed that the pitting potential for NiTi in artificial saliva decreased at low and high pH; at 25 degrees C, the pitting potential was the lowest compared to those at 10 degrees C, 37 degrees C and 50 degrees C; when the Cl- concentration was not less than 0.05 mol/L the pitting potential decreased with the increase of Cl- concentration. The free corrosion potential of austenitic NiTi was lower than that of mixture of austenite and martensite.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16977385     DOI: 10.1007/s10856-006-0178-7

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  8 in total

1.  Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva.

Authors:  Her-Hsiung Huang
Journal:  J Biomed Mater Res A       Date:  2003-09-15       Impact factor: 4.396

Review 2.  The utility of superelasticity in medicine.

Authors:  T W Duerig; A R Pelton; D Stöckel
Journal:  Biomed Mater Eng       Date:  1996       Impact factor: 1.300

Review 3.  On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys.

Authors:  S A Shabalovskaya
Journal:  Biomed Mater Eng       Date:  1996       Impact factor: 1.300

4.  An evaluation of 55 cobalt substituted Nitinol wire for use in orthodontics.

Authors:  G F Andreasen; T B Hilleman
Journal:  J Am Dent Assoc       Date:  1971-06       Impact factor: 3.634

5.  Distribution of nickel and cobalt following dermal and systemic administration with in vitro and in vivo studies.

Authors:  S A Lacy; K Merritt; S A Brown; A Puryear
Journal:  J Biomed Mater Res       Date:  1996-10

Review 6.  Electrochemical corrosion of metallic biomaterials.

Authors:  M Pourbaix
Journal:  Biomaterials       Date:  1984-05       Impact factor: 12.479

7.  Electrochemical and cytocompatibility assessment of NiTiNOL memory shape alloy for orthodontic use.

Authors:  L El Medawar; P Rocher; J-C Hornez; M Traisnel; J Breme; H F Hildebrand
Journal:  Biomol Eng       Date:  2002-08

8.  Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions.

Authors:  M Darabara; L Bourithis; S Zinelis; G D Papadimitriou
Journal:  Int Endod J       Date:  2004-10       Impact factor: 5.264

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.