Literature DB >> 15347296

Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions.

M Darabara1, L Bourithis, S Zinelis, G D Papadimitriou.   

Abstract

AIM: To evaluate the pitting and crevice corrosion characteristics of stainless steel (SS) and NiTi endodontic files in R-EDTA and NaOCl irrigating solutions.
METHODOLOGY: The corrosion behaviour of two H-files produced from different SS alloys (Mani, AISI 303 SS, Dentsply Maillefer, AISI 304 SS) and one file produced from NiTi alloy (Maillefer) was determined in R-EDTA and NaOCl irrigating solutions by the cyclic potentiodynamic polarization method. The cutting flutes of 12 files of each material were embedded in an epoxy resin, polished, exposed to the irrigating solutions and used as an electrode. An Ag/AgCl electrode was used as a reference, a platinum plate was used as a counter electrode and polarization curves were obtained for all files in R-EDTA and NaOCl irrigating solutions in 37 degrees C with a potential scan rate of 5 mV min(-1). Corrosion potential (Ecorr), Corrosion current density (Icorr) and Pitting potential (Epit) were calculated from each curve. The results were statistically analysed with two-way anova and Student-Newman-Keuls (SNK) multiple comparison test with materials and irrigating solutions serving as discriminating variables (a = 0.05).
RESULTS: Cyclic polarization curves presented negative hysteresis implying that pitting or crevice corrosion are not likely to occur for all the materials examined in both irrigating solutions. In NaOCl all materials showed significantly higher Ecorr (P = 0.011) as well as lower Icorr compared with R-EDTA reagent. Moreover, all materials demonstrated equal Epit in NaOCl, which was to be found significantly lower (P = 0.009) than the value of Epit in R-EDTA.
CONCLUSIONS: None of the tested materials is susceptible to pitting or crevice corrosion in R-EDTA and NaOCl solutions and from this standpoint are appropriate for the production of endodontic files.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15347296     DOI: 10.1111/j.1365-2591.2004.00866.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  10 in total

1.  Effect of pH, temperature and Cl- concentration on electrochemical behavior of NiTi shape memory alloy in artificial saliva.

Authors:  Jianqiu Wang; Nianxing Li; En-hou Han; Wei Ke
Journal:  J Mater Sci Mater Med       Date:  2006-10       Impact factor: 3.896

2.  The effect of electrical treatment on cyclic fatigue of NiTi instruments.

Authors:  Mohammad Ali Saghiri; Armen Asatourian; Franklin Garcia-Godoy; James L Gutmann; Mehrdad Lotfi; Nader Sheibani
Journal:  Scanning       Date:  2014-05-05       Impact factor: 1.932

3.  Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite.

Authors:  Hüseyin Sinan Topçuoğlu; Kanşad Pala; Ahmet Aktı; Salih Düzgün; Gamze Topçuoğlu
Journal:  Clin Oral Investig       Date:  2015-09-30       Impact factor: 3.573

4.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

5.  Influence of an Innovative Anti-Corrosive Solution on Resistance of Endodontic NiTi Rotary Instruments: A Preliminary Study.

Authors:  Mohammed Ali Saghiri; Armen Asatourian; Franklin Garcia Godoy; Nader Sheibani
Journal:  Eur Endod J       Date:  2017-12-21

6.  Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment.

Authors:  Tatiana Dias Costa; Elison da Fonseca E Silva; Paula Liparini Caetano; Marcio José da Silva Campos; Leandro Marques Resende; André Guimarães Machado; Antônio Márcio Resende do Carmo
Journal:  Restor Dent Endod       Date:  2020-12-28

7.  Effect of immersion in sodium hypochlorite on cyclic fatigue resistance of RaCe, HyFlex CM and XP-endo shaper files.

Authors:  Esmaeel Dadgar; Masoud Khabiri; Amin Mortaheb; Saeid Hoseini
Journal:  Dent Res J (Isfahan)       Date:  2022-07-18

8.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27

9.  Influence of Sodium Hypochlorite and Chlorhexidine on the Dynamic Cyclic Fatigue Resistance of XP Endo Shaper Instruments.

Authors:  Alexandra Aparecida Tanomaru; Ana Grasiela Limoeiro; Adriana de Jesus Soares; Elson Lopes Medeiros Junior; Gabriel Rocha Campos; Sílvia Kaoru Hamasaki; Wayne Martins Nascimento; Luiz Meton Horta; Paula Avelar da Silva Ribeiro Goulart; Viviane Rangel do Couto; Patrícia Bastos Alves; Verônica Magalhães; Danilo De Luca Campos; Marcos Frozoni
Journal:  Eur J Dent       Date:  2021-12-22

10.  A novel approach to determine the effect of irrigation on temperature and failure of Ni-Ti endodontic rotary files.

Authors:  Sayed Ali Mousavi; Vida Kargar-Dehnavi; Sayed Amir Mousavi
Journal:  Dent Res J (Isfahan)       Date:  2012-05
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.