Literature DB >> 16971799

Shape-constraint region growing for delineation of hepatic metastases on contrast-enhanced computed tomograph scans.

Binsheng Zhao1, Lawrence H Schwartz, Li Jiang, Jane Colville, Chaya Moskowitz, Liang Wang, Robert Leftowitz, Fan Liu, John Kalaigian.   

Abstract

OBJECTIVES: The objectives of this study were to develop a shape-constraint region-growing algorithm to automatically delineate liver metastases on computed tomography images and to compare automated tumor measurements with those outlined manually by radiologists.
METHODS: The algorithm starts with a manual selection of a seed lesion region of interest (ROI). Based on intensity distributions of the seed ROI and the liver parenchyma, several parameters are computed and used to adaptively guide the region growing. To prevent the region growing from leaking into surrounding tissues of similar characteristics, specific shape constraints, including a local shape, a global shape, and a gravity-shift index, are developed to jointly control the iteration of the region growing. The algorithm was applied to 59 lesions in 14 patients with liver metastases. The maximal diameter (unidimension), the product of the maximal and maximal perpendicular diameters (bidimension), and the area in the axial plane were calculated for each of the segmented lesions. Three independent radiologists manually measured all the lesions once, and one of the radiologists measured each lesion 3 times. For each measurement, the concordance correlation coefficient (CCC) was used to assess the pairwise agreement between the computer and the different radiologists, and the overall concordance correlation coefficient (OCCC) was used to assess the agreement between the computer and the multiple radiologists and between the one radiologist's 3 readings.
RESULTS: Fifty-three of 59 (89.8%) lesions in 14 patients with liver metastases were successfully segmented using this algorithm. The algorithm achieved a median accuracy of 88.0%. CCCs/OCCCs ranged from 0.943 to 0.999 with 95% confidence intervals.
CONCLUSIONS: High accuracy and CCCs/OCCCs suggested that measurements made by the computer were very similar to those made by the radiologists.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16971799     DOI: 10.1097/01.rli.0000236907.81400.18

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  17 in total

1.  Treatment planning and volumetric response assessment for Yttrium-90 radioembolization: semiautomated determination of liver volume and volume of tumor necrosis in patients with hepatic malignancy.

Authors:  Wayne L Monsky; Armando S Garza; Isaac Kim; Shaun Loh; Tzu-Chun Lin; Chin-Shang Li; Jerron Fisher; Parmbir Sandhu; Vishal Sidhar; Abhijit J Chaudhari; Frank Lin; Larry-Stuart Deutsch; Ramsey D Badawi
Journal:  Cardiovasc Intervent Radiol       Date:  2010-08-04       Impact factor: 2.740

Review 2.  Survey on Liver Tumour Resection Planning System: Steps, Techniques, and Parameters.

Authors:  Omar Ibrahim Alirr; Ashrani Aizzuddin Abd Rahni
Journal:  J Digit Imaging       Date:  2020-04       Impact factor: 4.056

3.  Multimodality 3D Tumor Segmentation in HCC Patients Treated with TACE.

Authors:  Zhijun Wang; Julius Chapiro; Rüdiger Schernthaner; Rafael Duran; Rongxin Chen; Jean-François Geschwind; MingDe Lin
Journal:  Acad Radiol       Date:  2015-04-08       Impact factor: 3.173

4.  Liver tumour segmentation using contrast-enhanced multi-detector CT data: performance benchmarking of three semiautomated methods.

Authors:  Jia-Yin Zhou; Damon W K Wong; Feng Ding; Sudhakar K Venkatesh; Qi Tian; Ying-Yi Qi; Wei Xiong; Jimmy J Liu; Wee-Kheng Leow
Journal:  Eur Radiol       Date:  2010-02-16       Impact factor: 5.315

5.  Comparison of two-dimensional and three-dimensional iterative watershed segmentation methods in hepatic tumor volumetrics.

Authors:  Shonket Ray; Rosalie Hagge; Marijo Gillen; Miguel Cerejo; Shidrokh Shakeri; Laurel Beckett; Tamara Greasby; Ramsey D Badawi
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

6.  Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria.

Authors:  Sebastian Keil; Florian F Behrendt; Sven Stanzel; Michael Sühling; Alexander Koch; Jhenee Bubenzer; Georg Mühlenbruch; Andreas H Mahnken; Rolf W Günther; Marco Das
Journal:  Eur Radiol       Date:  2008-06-04       Impact factor: 5.315

7.  Semiautomatic segmentation of liver metastases on volumetric CT images.

Authors:  Jiayong Yan; Lawrence H Schwartz; Binsheng Zhao
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

8.  Harnessing technology to improve clinical trials: study of real-time informatics to collect data, toxicities, image response assessments, and patient-reported outcomes in a phase II clinical trial.

Authors:  M Catherine Pietanza; Ethan M Basch; Alex Lash; Lawrence H Schwartz; Michelle S Ginsberg; Binsheng Zhao; Marwan Shouery; Mary Shaw; Lauren J Rogak; Manda Wilson; Aaron Gabow; Marcia Latif; Kai-Hsiung Lin; Qinfei Wu; Samantha L Kass; Claire P Miller; Leslie Tyson; Dyana K Sumner; Alison Berkowitz-Hergianto; Camelia S Sima; Mark G Kris
Journal:  J Clin Oncol       Date:  2013-04-29       Impact factor: 44.544

9.  Comparison of semi-automatic volumetric VX2 hepatic tumor segmentation from cone beam CT and multi-detector CT with histology in rabbit models.

Authors:  Olivier Pellerin; Mingde Lin; Nikhil Bhagat; Roberto Ardon; Benoit Mory; Jean-François Geschwind
Journal:  Acad Radiol       Date:  2012-09-02       Impact factor: 3.173

10.  Quantifying the margin sharpness of lesions on radiological images for content-based image retrieval.

Authors:  Jiajing Xu; Sandy Napel; Hayit Greenspan; Christopher F Beaulieu; Neeraj Agrawal; Daniel Rubin
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071