Literature DB >> 16970184

Column selectivity for two-dimensional liquid chromatography.

Pavel Jandera1.   

Abstract

Selectivity of phase system is of primary concern when designing a 2-D separation, as it affects the 2-D system orthogonality and consequently the peak capacity controlling the number of peaks that can be separated in the available 2-D retention space limited by the time of analysis. Possibilities for characterization of LC phase system selectivity with respect to different polar and nonpolar structural units are compared, with special attention to multidimensional samples with various types of repeat groups, such as homopolymers, (co)polymers, fatty acid esters with various acyl lengths and number and position of double bonds, etc. Possibilities of the 2-D LC separations of these and other sample types, including pharmaceuticals, natural phenolic compounds, biopolymers, etc., using various combinations of separation modes are reviewed. Rules for design of comprehensive 2-D LC x LC systems are discussed, with respect to mobile phase compatibility in the two systems and modulation techniques suppressing band broadening connected with the sample fraction transfer from the first to the second dimension. Pitfalls connected with online connection of normal-phase and RP LC systems and their possible practical solutions are addressed and illustrated by practical examples.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16970184     DOI: 10.1002/jssc.200600202

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  5 in total

Review 1.  Fast, comprehensive two-dimensional liquid chromatography.

Authors:  Dwight R Stoll; Xiaoping Li; Xiaoli Wang; Peter W Carr; Sarah E G Porter; Sarah C Rutan
Journal:  J Chromatogr A       Date:  2007-08-30       Impact factor: 4.759

2.  Evaluation of the identification power of RPLC analyses in the screening for drug compounds.

Authors:  Melanie Dumarey; Yvan Vander Heyden; Sarah C Rutan
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

Review 3.  Hydrophilic interaction liquid chromatography (HILIC)--a powerful separation technique.

Authors:  Bogusław Buszewski; Sylwia Noga
Journal:  Anal Bioanal Chem       Date:  2011-08-31       Impact factor: 4.142

4.  A validated LC-MS/MS assay for quantification of 24(S)-hydroxycholesterol in plasma and cerebrospinal fluid.

Authors:  Rohini Sidhu; Hui Jiang; Nicole Y Farhat; Nuria Carrillo-Carrasco; Myra Woolery; Elizabeth Ottinger; Forbes D Porter; Jean E Schaffer; Daniel S Ory; Xuntian Jiang
Journal:  J Lipid Res       Date:  2015-04-12       Impact factor: 5.922

5.  Simultaneous analysis of defense-related phytohormones in Arabidopsis thaliana responding to fungal infection.

Authors:  Katlego B Riet; Nombuso Ndlovu; Lizelle A Piater; Ian A Dubery
Journal:  Appl Plant Sci       Date:  2016-08-23       Impact factor: 1.936

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.