Anisotropic imaging performance in indirect x-ray imaging detectors.

Aldo Badano1, Iacovos S Kyprianou, Josep Sempau.   

Abstract

We report on the variability in imaging system performance due to oblique x-ray incidence, and the associated transport of quanta (both x rays and optical photons) through the phosphor, in columnar indirect digital detectors. The analysis uses MANTIS, a combined x-ray, electron, and optical Monte Carlo transport code freely available. We describe the main features of the simulation method and provide some validation of the phosphor screen models considered in this work. We report x-ray and electron three-dimensional energy deposition distributions and point-response functions (PRFs), including optical spread in columnar phosphor screens of thickness 100 and 500 microm, for 19, 39, 59, and 79 keV monoenergetic x-ray beams incident at 0 degrees, 10 degrees, and 15 degrees. In addition, we present pulse-height spectra for the same phosphor thickness, x-ray energies, and angles of incidence. Our results suggest that the PRF due to the phosphor blur is highly nonsymmetrical, and that the resolution properties of a columnar screen in a tomographic, or tomosynthetic imaging system varies significantly with the angle of x-ray incidence. Moreover, we find that the noise due to the variability in the number of light photons detected per primary x-ray interaction, summarized in the information or Swank factor, is somewhat independent of thickness and incidence angle of the x-ray beam. Our results also suggest that the anisotropy in the PRF is not less in screens with absorptive backings, while the noise introduced by variations in the gain and optical transport is larger. Predictions from MANTIS, after additional validation, can provide the needed understanding of the extent of such variations, and eventually, lead to the incorporation of the changes in imaging performance with incidence angle into the reconstruction algorithms for volumetric x-ray imaging systems.

Entities:  

Mesh:

Year:  2006        PMID: 16967568     DOI: 10.1118/1.2208925

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems.

Authors:  Melanie Freed; Subok Park; Aldo Badano
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  Singular value description of a digital radiographic detector: theory and measurements.

Authors:  Iacovos S Kyprianou; Aldo Badano; Brandon D Gallas; Kyle J Myers
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: a preliminary study.

Authors:  I Reiser; R M Nishikawa; A V Edwards; D B Kopans; R A Schmidt; J Papaioannou; R H Moore
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

5.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

6.  Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

7.  Dual-energy contrast-enhanced breast tomosynthesis: optimization of beam quality for dose and image quality.

Authors:  Ehsan Samei; Robert S Saunders
Journal:  Phys Med Biol       Date:  2011-09-09       Impact factor: 3.609

8.  Deriving depth-dependent light escape efficiency and optical Swank factor from measured pulse height spectra of scintillators.

Authors:  Adrian Howansky; Boyu Peng; Anthony R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2017-02-13       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.