Literature DB >> 16965976

Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems.

Mark Hastenteufel1, Marcus Vetter, Hans-Peter Meinzer, Ivo Wolf.   

Abstract

In the last few years, 3D ultrasound probes have became readily available. New fields of image-guided surgery applications are opened by attaching small electromagnetic position sensors to 3D ultrasound probes. However, nothing is known about the distortions caused by 3D ultrasound probes regarding electromagnetic sensors. Several trials were performed to investigate error-proneness of state-of-the-art electromagnetic tracking systems when used in combination with 3D ultrasound probes. It was found that 3D ultrasound probes do distort electromagnetic sensors more than 2D probes do. When attaching electromagnetic sensors to 3D probes, maximum errors of 5 mm up to 119 mm occur. The distortion strongly depends on the electromagnetic technology as well on the probe technology used. Thus, for 3D ultrasound-guided applications using electromagnetic tracking technology, the interference of ultrasound probes and electromagnetic sensors have to be checked carefully.

Mesh:

Year:  2006        PMID: 16965976     DOI: 10.1016/j.ultrasmedbio.2006.05.013

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator.

Authors:  A M Franz; K März; J Hummel; W Birkfellner; R Bendl; S Delorme; H-P Schlemmer; H-P Meinzer; L Maier-Hein
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-05-24       Impact factor: 2.924

2.  [New developments in computer-assisted surgery (CAS). From intraoperative imaging to ultrasound-based navigation].

Authors:  P A Federspil
Journal:  HNO       Date:  2009-10       Impact factor: 1.284

Review 3.  Navigated laparoscopic ultrasound in abdominal soft tissue surgery: technological overview and perspectives.

Authors:  Thomas Langø; Sinara Vijayan; Anna Rethy; Cecilie Våpenstad; Ole Vegard Solberg; Ronald Mårvik; Gjermund Johnsen; Toril N Hernes
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-03       Impact factor: 2.924

4.  Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy.

Authors:  Elodie Lugez; Hossein Sadjadi; Chandra P Joshi; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-18       Impact factor: 2.924

Review 5.  Enhancement of needle visualization and localization in ultrasound.

Authors:  Parmida Beigi; Septimiu E Salcudean; Gary C Ng; Robert Rohling
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-09-30       Impact factor: 2.924

6.  A 3D multi-modal intelligent intervention system using electromagnetic navigation for real-time positioning and ultrasound images: a prospective randomized controlled trial.

Authors:  Weiwei Tang; Yun Zhou; Hui Zhao; Guangshun Sun; Dawei Rong; Zhitao Li; Meng Hu; Liu Han; Xu He; Suming Zhao; Xiaoyang Chen; Zhongming Li; Hongxin Yuan; Songwang Chen; Qian Wang; Zhouxiao Li; Jianping Gu; Xuehao Wang; Jinhua Song
Journal:  Ann Transl Med       Date:  2022-06

Review 7.  Performance and suitability assessment of a real-time 3D electromagnetic needle tracking system for interstitial brachytherapy.

Authors:  Samir Boutaleb; Emmanuel Racine; Olivier Fillion; Antonio Bonillas; Gilion Hautvast; Dirk Binnekamp; Luc Beaulieu
Journal:  J Contemp Brachytherapy       Date:  2015-09-14

8.  Development and Phantom Validation of a 3-D-Ultrasound-Guided System for Targeting MRI-Visible Lesions During Transrectal Prostate Biopsy.

Authors:  Yipeng Hu; Veeru Kasivisvanathan; Lucy A M Simmons; Matthew J Clarkson; Stephen A Thompson; Taimur T Shah; Hashim U Ahmed; Shonit Punwani; David J Hawkes; Mark Emberton; Caroline M Moore; Dean C Barratt
Journal:  IEEE Trans Biomed Eng       Date:  2016-06-21       Impact factor: 4.538