Literature DB >> 16965975

Design and characterisation of a wall motion phantom.

J Dineley1, S Meagher, T L Poepping, W N McDicken, P R Hoskins.   

Abstract

Arterial wall motion is an essential feature of a healthy cardiovascular system and it is known that wall motion is affected by age and disease. In recent years, methods have been developed for measurement of wall motion with the intention of providing diagnostically useful information. An issue with all of these techniques is the accuracy and variability of both wall motion and derived quantities such as elasticity, which requires the development of suitable test tools. In this paper, a vessel wall phantom is described for use in ultrasound studies of wall motion. The vessel was made from polyvinyl alcohol (PVA) subjected to a freeze-thaw process to form a cryogel (PVA-C). The elastic modulus, acoustic velocity and attenuation coefficient varied from 57 kPa, 1543 m s(-1) and 0.18 dB cm(-1) MHz(-1) for one freeze-thaw cycle to 330 kPa, 1583 m s(-1) and 0.42 dB cm(-1) MHz(-1) for 10 freeze-thaw cycles. Wall motion was effected by the use of pulsatile flow produced from a gear pump. The use of a downstream flow resistor removed gross distortions in the wall motion waveform, possibly by removal of reflected pressure waves. However, a low amplitude 20 Hz oscillation remained, which is unphysiologic and thought to be caused by the vibration of the distended PVA-C vessel.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16965975     DOI: 10.1016/j.ultrasmedbio.2006.05.033

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  Pipe Phantoms With Applications in Molecular Imaging and System Characterization.

Authors:  Shiying Wang; Elizabeth B Herbst; Stephen D Pye; Carmel M Moran; John A Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11-09       Impact factor: 2.725

2.  Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow.

Authors:  Kenichi Funamoto; Osamu Yamashita; Toshiyuki Hayase
Journal:  J Med Ultrason (2001)       Date:  2014-08-05       Impact factor: 1.314

3.  Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging.

Authors:  Steven Fortune; Maurits A Jansen; Tom Anderson; Gillian A Gray; Jürgen E Schneider; Peter R Hoskins; Ian Marshall
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

4.  Regional in vivo transit time measurements of aortic pulse wave velocity in mice with high-field CMR at 17.6 Tesla.

Authors:  Marco Parczyk; Volker Herold; Gert Klug; Wolfgang R Bauer; Eberhard Rommel; Peter M Jakob
Journal:  J Cardiovasc Magn Reson       Date:  2010-12-06       Impact factor: 5.364

5.  Wall-less flow phantom for high-frequency ultrasound applications.

Authors:  David A Kenwright; Nicola Laverick; Tom Anderson; Carmel M Moran; Peter R Hoskins
Journal:  Ultrasound Med Biol       Date:  2014-12-23       Impact factor: 2.998

6.  Influence of vascular geometry on local hemodynamic parameters: phantom and small rodent study.

Authors:  Lili Niu; Xiliang Zhu; Min Pan; Abbott Derek; Lisheng Xu; Long Meng; Hairong Zheng
Journal:  Biomed Eng Online       Date:  2018-03-02       Impact factor: 2.819

7.  A simple, realistic walled phantom for intravascular and intracardiac applications.

Authors:  Hareem Nisar; John Moore; Roberta Piazza; Efthymios Maneas; Elvis C S Chen; Terry M Peters
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-06-10       Impact factor: 2.924

8.  Deep bleeder acoustic coagulation (DBAC)-Part I: development and in vitro testing of a research prototype cuff system.

Authors:  K Michael Sekins; Stephen R Barnes; Liexiang Fan; Jerry D Hopple; Stephen J Hsu; John Kook; Chi-Yin Lee; Caroline Maleke; A R Ramachandran; Xiaozheng Jenny Zeng; Romain Moreau-Gobard; Alexis Ahiekpor-Dravi; Gareth Funka-Lea; Stuart B Mitchell; Barbrina Dunmire; John C Kucewicz; John Eaton; Keith Wong; Scott Keneman; Lawrence A Crum
Journal:  J Ther Ultrasound       Date:  2015-09-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.