Literature DB >> 16964871

64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: an ex vivo study.

D Melodelima1, R Salomir, C Mougenot, C Moonen, D Cathignol.   

Abstract

This work was undertaken to investigate the feasibility of using a cylindrical phased array for transoesophaeal thermal ablation under magnetic resonance (MR) imaging guidance. Sixty-four transducers (0.45 mm wide by 15 mm tall), operating at 4.6 MHz, were spread around the periphery of a 10.6-mm-diam cylinder. The head of the applicator was covered with a 65-microm thick latex balloon attached using watertight seals. This envelope was inflated with degassed water to provide acoustic coupling between the transducer and the tissues. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. Ex vivo experiments conducted on 47 samples of pig liver under MR temperature monitoring demonstrated the ability of this applicator to generate cylindrical or sector-based coagulation necroses at depths up to 19 mm with excellent angular precision by applying 20 W/cm2. MR thermometry was performed in "real-time" with segmented echo-planar imaging gradient echo sequences. The temporal resolution was approximately 3 s/ image. The average value for the temperature baseline in liver tissue close to the applicator was 0.3 degrees C (+/- 0.6 degrees C). The thermal dose delivered in tissues was computed on-line during temperature imaging. Excellent MR compatibility was demonstrated, all MR acquisitions were performed without susceptibility artifacts or radio-frequency interferences with the ultrasound device. Thermal lesions identified on post-treatment follow up showed good correlation with online MR thermometry data. The individual differences between measurements performed visually and using MRI thermal dose maps were about 11% of volume. This study demonstrated the feasibility of thermal ablation using a phased array intraluminal ultrasound applicator and on-line MR monitoring.

Entities:  

Mesh:

Year:  2006        PMID: 16964871      PMCID: PMC1890449          DOI: 10.1118/1.2218064

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  38 in total

1.  Feasibility of linear arrays for interstitial ultrasound thermal therapy.

Authors:  R Chopra; M J Bronskill; F S Foster
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

2.  Interstitial ultrasound heating applicator for MR-guided thermal therapy.

Authors:  R Chopra; C Luginbuhl; A J Weymouth; F S Foster; M J Bronskill
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

3.  MR-guided microwave thermocoagulation therapy of liver tumors: initial clinical experiences using a 0.5 T open MR system.

Authors:  Shigehiro Morikawa; Toshiro Inubushi; Yoshimasa Kurumi; Shigeyuki Naka; Koichiro Sato; Tohru Tani; Ikuo Yamamoto; Masaki Fujimura
Journal:  J Magn Reson Imaging       Date:  2002-11       Impact factor: 4.813

Review 4.  Intradiscal electrothermal therapy used to manage chronic discogenic low back pain: new directions and interventions.

Authors:  F Todd Wetzel; Thomas A McNally; Frank M Phillips
Journal:  Spine (Phila Pa 1976)       Date:  2002-11-15       Impact factor: 3.468

5.  Ultrasound cylindrical phased array for transoesophageal thermal therapy: initial studies.

Authors:  David Melodelima; Cyril Lafon; Frederic Prat; Alain Birer; Dominique Cathignol
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

6.  1.5-D high intensity focused ultrasound array for non-invasive prostate cancer surgery.

Authors:  L Curiel; F Chavrier; R Souchon; A Birer; J Y Chapelon
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-02       Impact factor: 2.725

7.  Expandable metal stents versus laser combined with radiotherapy for palliation of unresectable esophageal cancer: a prospective randomized trial.

Authors:  A Königsrainer; B Riedmann; A De Vries; D Ofner; B Spechtenhauser; F Aigner; E Fritsch; R Margreiter
Journal:  Hepatogastroenterology       Date:  2000 May-Jun

8.  Magnetic resonance imaging-guided focused ultrasound thermal therapy in experimental animal models: correlation of ablation volumes with pathology in rabbit muscle and VX2 tumors.

Authors:  John D Hazle; R Jason Stafford; Roger E Price
Journal:  J Magn Reson Imaging       Date:  2002-02       Impact factor: 4.813

9.  Endoscopic treatment of cholangiocarcinoma and carcinoma of the duodenal papilla by intraductal high-intensity US: Results of a pilot study.

Authors:  Frédéric Prat; Cyril Lafon; David Melo De Lima; Yves Theilliere; Jacques Fritsch; Gilles Pelletier; Catherine Buffet; Dominique Cathignol
Journal:  Gastrointest Endosc       Date:  2002-12       Impact factor: 9.427

10.  Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh.

Authors:  Jean Palussière; Rares Salomir; Brigitte Le Bail; Rabia Fawaz; Bruno Quesson; Nicolas Grenier; Chrit T W Moonen
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

View more
  7 in total

1.  Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results.

Authors:  J Chenot; D Melodelima; W A N'djin; Rémi Souchon; M Rivoire; J Y Chapelon
Journal:  Phys Med Biol       Date:  2010-05-17       Impact factor: 3.609

Review 2.  Catheter-based ultrasound technology for image-guided thermal therapy: current technology and applications.

Authors:  Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2015-03-23       Impact factor: 3.914

3.  Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.

Authors:  Muhammad Zubair; Matthew S Adams; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2021-08-10       Impact factor: 3.914

4.  Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: in vivo evaluation under MR guidance.

Authors:  Adam M Kinsey; Chris J Diederich; Viola Rieke; William H Nau; Kim Butts Pauly; Donna Bouley; Graham Sommer
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

5.  Thermal therapy of pancreatic tumours using endoluminal ultrasound: Parametric and patient-specific modelling.

Authors:  Matthew S Adams; Serena J Scott; Vasant A Salgaonkar; Graham Sommer; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2016-01-21       Impact factor: 3.914

6.  High-intensity focused ultrasound ablation for the treatment of colorectal liver metastases during an open procedure: study on the pig.

Authors:  Hubert Parmentier; Parmentier Hubert; David Melodelima; Melodelima David; Apoutou N'Djin; N'Djin Apoutou; Sabrina Chesnais; Chesnais Sabrina; Jean Yves Chapelon; Chapelon Jean Yves; Michel Rivoire; Rivoire Michel
Journal:  Ann Surg       Date:  2009-01       Impact factor: 12.969

7.  Treatment of esophageal tumors using high intensity intraluminal ultrasound: first clinical results.

Authors:  David Melodelima; Frederic Prat; Jacques Fritsch; Yves Theillere; Dominique Cathignol
Journal:  J Transl Med       Date:  2008-06-05       Impact factor: 5.531

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.