Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters.

A A Birch1, C A Eynon, D Schley.   

Abstract

The objective of this report is to highlight the potential for false pressure measurements from systems that combine intracranial pressure (ICP) measurement and ventricular drainage. If the ports of the drain become blocked to the extent that they present a high resistance to cerebrospinal fluid flow, then a significant pressure gradient between the inside and outside of the catheter may be established. Thus, any intracatheter transducer will faithfully record a pressure much lower than true ICP. This holds true for catheter-tip transducers when the transducer lies inside the catheter. In the absence of flow, however, pressures will equalize; therefore, accurate measurements may be taken if the drain is temporarily closed. We model this situation and provide simulations of expected measurements in such situations; these compare well to observed clinical readings.

Mesh:

Year:  2006        PMID: 16960297     DOI: 10.1385/NCC:5:1:51

Source DB:  PubMed          Journal:  Neurocrit Care        ISSN: 1541-6933            Impact factor:   3.210


  5 in total

1.  A model of in-vivo hydrocephalus shunt dynamics for blockage and performance diagnostics.

Authors:  D Schley; J Billingham; R J Marchbanks
Journal:  Math Med Biol       Date:  2004-12       Impact factor: 1.854

2.  The influence of variations in temperature and blood-pressure on the performance of the isolated mammalian heart.

Authors:  F P Knowlton; E H Starling
Journal:  J Physiol       Date:  1912-05-06       Impact factor: 5.182

3.  Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC)and an integrated Piezo-resistive sensor at its tip: technical note.

Authors:  J Piek; P Raes
Journal:  Neurosurgery       Date:  1996-01       Impact factor: 4.654

4.  Erroneous measurement of intracranial pressure caused by simultaneous ventricular drainage: a hydrodynamic model study.

Authors:  H A Wilkinson; J Yarzebski; E C Wilkinson; F A Anderson
Journal:  Neurosurgery       Date:  1989-03       Impact factor: 4.654

5.  A Starling resistor regulates cerebral venous outflow in dogs.

Authors:  J M Luce; J S Huseby; W Kirk; J Butler
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-12
  5 in total
  8 in total

1.  Emergency Neurological Life Support: Severe Traumatic Brain Injury.

Authors:  Rachel Garvin; Halinder S Mangat
Journal:  Neurocrit Care       Date:  2017-09       Impact factor: 3.210

Review 2.  Emergency Neurological Life Support: Traumatic Brain Injury.

Authors:  Rachel Garvin; Chitra Venkatasubramanian; Angela Lumba-Brown; Chad M Miller
Journal:  Neurocrit Care       Date:  2015-12       Impact factor: 3.210

Review 3.  Physiological monitoring of the severe traumatic brain injury patient in the intensive care unit.

Authors:  Peter Le Roux
Journal:  Curr Neurol Neurosci Rep       Date:  2013-03       Impact factor: 5.081

4.  Fluidic Considerations of Measuring Intracranial Pressure Using an Open External Ventricular Drain.

Authors:  Peter G Beidler; Alexander Novokhodko; Laura M Prolo; Samuel Browd; Barry R Lutz
Journal:  Cureus       Date:  2021-05-29

5.  Intracranial multimodal monitoring for acute brain injury: a single institution review of current practices.

Authors:  R Morgan Stuart; Michael Schmidt; Pedro Kurtz; Allen Waziri; Raimund Helbok; Stephan A Mayer; Kiwon Lee; Neeraj Badjatia; Lawrence J Hirsch; E Sander Connolly; Jan Claassen
Journal:  Neurocrit Care       Date:  2010-04       Impact factor: 3.210

6.  Observation of Autoregulation Indices During Ventricular CSF Drainage After Aneurysmal Subarachnoid Hemorrhage: A Pilot Study.

Authors:  Marcel J H Aries; Sytse F de Jong; J Marc C van Dijk; Joost Regtien; Bart Depreitere; Marek Czosnyka; Peter Smielewski; Jan Willem J Elting
Journal:  Neurocrit Care       Date:  2015-12       Impact factor: 3.210

Review 7.  Management of raised intracranial pressure in children with traumatic brain injury.

Authors:  Vinay Kukreti; Hadi Mohseni-Bod; James Drake
Journal:  J Pediatr Neurosci       Date:  2014 Sep-Dec

Review 8.  Measuring intracranial pressure by invasive, less invasive or non-invasive means: limitations and avenues for improvement.

Authors:  Karen Brastad Evensen; Per Kristian Eide
Journal:  Fluids Barriers CNS       Date:  2020-05-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.