OBJECTIVE: To evaluate the degree of enhancement and image quality of chest computed tomographic (CT) examinations on 16-slice multidetector CT using low-concentration [300 milligrams of iodine per milliliter (mg I/mL)] and high-concentration (370 mg I/mL) contrast media; to assess the impact on cost and adverse reactions of the use of high-iodine concentration contrast medium. MATERIALS AND METHODS: A total of 100 patients scheduled for routine chest CT examinations were administered nonionic contrast medium of 2 strengths: low-iodine concentration contrast medium (300 mg I/mL) [group A: n = 50; male-female ratio, 28:22; mean age, 58.4 years] and high-iodine concentration contrast medium (370 mg I/mL) (group B: n = 50; male-female ratio, 18:32; mean age, 57.6 years) with a constant amount of iodine (400 mg) injected per kilogram of body weight. Contrast media were injected using a dual injector at 2.5 mL/s followed by a 30-mL saline at 2.5 mL/s. The degree of enhancement was quantified by measuring Hounsfield unit values in different arteries and veins and was also rated on a 5-point scale for qualitative assessment. We also evaluated perivenous contrast-related artifacts. The data were compared using Mann-Whitney U test for both qualitative and quantitative enhancement ratings. A value of less than 0.05 was considered statistically significant. The value was adjusted using Bonferroni correction for statistical significance when multiple comparisons were performed. The difference in cost and the incidence of adverse reactions in both groups were calculated. RESULTS: The mean enhancement values in group B were significantly greater (P < 0.05) than those in group A. The mean Hounsfield units and standard deviation in groups A and B were aorta = 153 +/- 4, 216 +/- 20; pulmonary artery = 147 +/- 10, 208 +/- 20; superior vena cava = 155 +/- 27, 299 +/- 72; and pulmonary vein = 134 +/- 10, 215 +/- 30, respectively. The mean enhancement on a 5-point scale was greater in group B (4.2) than in group A (3.3) (P < 0.01). No significant difference between groups in perivenous artifacts was seen. Up to 5.5% savings in cost resulted from the use of a higher concentration of iodine, with no increase in adverse reactions. CONCLUSIONS: Use of higher-concentration contrast media provides a higher degree of contrast enhancement and image quality for a routine chest CT on a 16-slice multidetector CT. It also contributes to considerable cost savings with no increased risk of adverse reactions compared with low-concentration contrast media.
RCT Entities:
OBJECTIVE: To evaluate the degree of enhancement and image quality of chest computed tomographic (CT) examinations on 16-slice multidetector CT using low-concentration [300 milligrams of iodine per milliliter (mg I/mL)] and high-concentration (370 mg I/mL) contrast media; to assess the impact on cost and adverse reactions of the use of high-iodine concentration contrast medium. MATERIALS AND METHODS: A total of 100 patients scheduled for routine chest CT examinations were administered nonionic contrast medium of 2 strengths: low-iodine concentration contrast medium (300 mg I/mL) [group A: n = 50; male-female ratio, 28:22; mean age, 58.4 years] and high-iodine concentration contrast medium (370 mg I/mL) (group B: n = 50; male-female ratio, 18:32; mean age, 57.6 years) with a constant amount of iodine (400 mg) injected per kilogram of body weight. Contrast media were injected using a dual injector at 2.5 mL/s followed by a 30-mL saline at 2.5 mL/s. The degree of enhancement was quantified by measuring Hounsfield unit values in different arteries and veins and was also rated on a 5-point scale for qualitative assessment. We also evaluated perivenous contrast-related artifacts. The data were compared using Mann-Whitney U test for both qualitative and quantitative enhancement ratings. A value of less than 0.05 was considered statistically significant. The value was adjusted using Bonferroni correction for statistical significance when multiple comparisons were performed. The difference in cost and the incidence of adverse reactions in both groups were calculated. RESULTS: The mean enhancement values in group B were significantly greater (P < 0.05) than those in group A. The mean Hounsfield units and standard deviation in groups A and B were aorta = 153 +/- 4, 216 +/- 20; pulmonary artery = 147 +/- 10, 208 +/- 20; superior vena cava = 155 +/- 27, 299 +/- 72; and pulmonary vein = 134 +/- 10, 215 +/- 30, respectively. The mean enhancement on a 5-point scale was greater in group B (4.2) than in group A (3.3) (P < 0.01). No significant difference between groups in perivenous artifacts was seen. Up to 5.5% savings in cost resulted from the use of a higher concentration of iodine, with no increase in adverse reactions. CONCLUSIONS: Use of higher-concentration contrast media provides a higher degree of contrast enhancement and image quality for a routine chest CT on a 16-slice multidetector CT. It also contributes to considerable cost savings with no increased risk of adverse reactions compared with low-concentration contrast media.
Authors: Baskaran Sundaram; Jean W Kuriakose; Jadranka Stojanovska; Kuanwong Watcharotone; Robert A Parker; Ella A Kazerooni Journal: Clin Imaging Date: 2015-02-12 Impact factor: 1.605
Authors: S Keil; C Plumhans; F F Behrendt; M Das; S Stanzel; G Mühlenbruch; P Seidensticker; C Knackstedt; A H Mahnken; R W Günther; J E Wildberger Journal: Eur Radiol Date: 2008-04-08 Impact factor: 5.315
Authors: Florian F Behrendt; Hubertus Pietsch; Gregor Jost; Martin A Sieber; Sebastian Keil; Cedric Plumhans; Peter Seidensticker; Rolf W Günther; Andreas H Mahnken Journal: Eur Radiol Date: 2010-02-24 Impact factor: 5.315
Authors: Georg Mühlenbruch; Florian F Behrendt; Mohammed A Eddahabi; Christian Knackstedt; Sven Stanzel; Marco Das; Peter Seidensticker; Rolf W Günther; Joachim E Wildberger; Andreas H Mahnken Journal: Eur Radiol Date: 2008-07-24 Impact factor: 5.315