Literature DB >> 16953352

Effective disinfection of orthodontic pliers.

Andrea Wichelhaus1, Friedel Bader, Franz Günter Sander, Dorothea Krieger, Thomas Mertens.   

Abstract

OBJECTIVE: Pathogenic microbes may be transmitted directly from the orthodontist to the patient or from the patient to the doctor, and indirectly from patient to patient. The latter may occur via contaminated instruments or surfaces, and is referred to as cross-contamination. The objective of this study was to evaluate the extent of bacterial contamination of orthodontic pliers and the efficacy of the disinfection techniques applied after clinical use. We also sought to examine under standardized conditions the virucidal, bactericidal and fungicidal effects of disinfection techniques used in practice.
MATERIALS AND METHODS: The efficacy of various disinfection methods was determined after clinical use in-vivo on 10 test subjects and in-vitro with deliberate contamination. The following disinfection methods were tested: 1. Iso-Septol spray 2. Incidur spray 3. Trough disinfection in combination with 5% Sekusept Plus solution 4. Ultrasound bath in combination with 5% Sekusept Plus solution 5. Thermal disinfection For in-vitro contamination we used the test organisms Staphylococcus aureus, Escherichia coli, Candida albicans, Coxsackie virus B4, HSV 1, and Adenovirus type 5. The tests were carried out six to eight times for each organism. The Weingart pliers and distalend cutters were tested. The criteria for effective disinfection were a reduction in infectiosity of five log steps (for bacteria and fungi) or four log steps (viruses). Statistical analysis was carried out using the Wilcoxon and Whitney U-test.
RESULTS: The presence of contamination following clinical use was not adequately eliminated with all disinfection methods. The spray methods exhibited shortcomings in disinfection. For the type of contamination defined, trough disinfection with 5% Sekusept Plus and the Incidur and Iso-Septol spray disinfection methods provided insufficient disinfection. Conversely, the ultrasound bath with 5% Sekusept Plus solution and steam disinfection met the criteria for effective disinfection for all microbes. No statistically significant difference was found between the oiled and unoiled states. In some cases, there were slightly higher rates of contamination with the Weingart pliers as with the distalend cutters. However, these were not statistically significant.
CONCLUSIONS: It should be possible to disinfect lipophilic viruses and the usual bacterial infections adequately with all methods, provided that the use of sprays and trough disinfection is preceded by cleaning with brush and water, followed by drying. With hydrophilic viruses, however, the spray and trough disinfection methods are limited in their efficacy and cannot be considered adequate. Exclusively chemical methods are therefore less effective than thermal or physical-chemical methods. Thermal disinfection and the ultrasound bath in combination with 5% Sekusept Plus are clearly superior to spray disinfection and trough disinfection alone. The ultrasound bath and thermal disinfection can therefore be recommended for the disinfection of orthodontic pliers. We recommend that the pliers be cleaned beforehand due to their uneven surfaces.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16953352     DOI: 10.1007/s00056-006-0622-9

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  6 in total

1.  Microbial contamination of orthodontic buccal tubes from manufacturers.

Authors:  Kathiravan Purmal; Shenyang Chin; John Pinto; Wai-Fong Yin; Kok-Gan Chan
Journal:  Int J Mol Sci       Date:  2010-09-16       Impact factor: 5.923

2.  Evaluation of the Compliance of Orthodontists to Infection Control Procedures in Turkey.

Authors:  Asuman Deniz Gümrü Çelikel; Hasan Ekmekçioğlu; Güven Külekçi; Sönmez Fıratlı
Journal:  Turk J Orthod       Date:  2018-04-11

Review 3.  Precautions and recommendations for orthodontic settings during the COVID-19 outbreak: A review.

Authors:  Khadijah A Turkistani
Journal:  Am J Orthod Dentofacial Orthop       Date:  2020-05-13       Impact factor: 2.650

Review 4.  Challenges, limitations, and solutions for orthodontists during the coronavirus pandemic: A review.

Authors:  Milad Malekshoar; Mehrdad Malekshoar; Bahareh Javanshir
Journal:  Am J Orthod Dentofacial Orthop       Date:  2020-10-19       Impact factor: 2.650

5.  Comparison of three different sterilization and disinfection methods on orthodontic markers.

Authors:  Maryam Omidkhoda; Roozbeh Rashed; Zahra Bagheri; Kiarash Ghazvini; Hooman Shafaee
Journal:  J Orthod Sci       Date:  2016 Jan-Mar

6.  Effect of Different Disinfectants on Bacterial Aerosol Diversity in Poultry Houses.

Authors:  Linlin Jiang; Meng Li; Jinxiu Tang; Xiaoyu Zhao; Jianlong Zhang; Hongwei Zhu; Xin Yu; Youzhi Li; Tao Feng; Xingxiao Zhang
Journal:  Front Microbiol       Date:  2018-09-11       Impact factor: 5.640

  6 in total