Evaluation of the Compliance of Orthodontists to Infection Control Procedures in Turkey.

Asuman Deniz Gümrü Çelikel1, Hasan Ekmekçioğlu2, Güven Külekçi3, Sönmez Fıratlı1.   

Abstract

OBJECTIVE: Orthodontists do not perform surgical procedures, nevertheless they are obliged to practice appropriate sterilization techniques to prevent cross-infection. This is also important from an ethical and legal point of view. The aim of the present study is to evaluate the compliance of orthodontists to infection control procedures in Turkey.
METHODS: A questionnaire with 36 items was delivered by e-mail to a total of 1152 orthodontists/residents between October 2014 and March 2015 by the Turkish Orthodontic Society. Various data from surveys were analyzed using the IBM SPSS statistics 22 software.
RESULTS: The questionnaire was completed by 130 (11.28%) respondents. 95.4% of the orthodontists were immunized against hepatitis B. The usage rates of type B autoclave, non-type B autoclave, and dry-heat sterilizer were 40%, 17.7%, and 16.9%, respectively. A total of 24.6% of the orthodontists used disinfectant solutions for the sterilization of hand instruments and pliers; the rate of using disinfectants for the sterilization of dental handpieces was found to be higher (56.9%).
CONCLUSION: The infection control procedures in the field of orthodontics must be improved in Turkey. Training on compliance with the infection control principles should be included in education programs, and these programs should be repeated on a regular basis.

Entities:  

Keywords:  Orthodontics; disinfection; infection control procedure; sterilization

Year:  2018        PMID: 30112513      PMCID: PMC6046636          DOI: 10.5152/TurkJOrthod.2018.17036

Source DB:  PubMed          Journal:  Turk J Orthod        ISSN: 2148-9505


  21 in total

1.  Effect of steam versus dry-heat sterilization on the wear of orthodontic ligature-cutting pliers.

Authors:  Ricardo J Vendrell; Curtis L Hayden; Louis J Taloumis
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-05       Impact factor: 2.650

2.  Trends in sterilization and disinfection procedures in orthodontic offices.

Authors:  R G Cash
Journal:  Am J Orthod Dentofacial Orthop       Date:  1990-10       Impact factor: 2.650

3.  Sterilization of orthodontic instruments and bands in cassettes.

Authors:  W F Hohlt; C H Miller; J M Neeb; M A Sheldrake
Journal:  Am J Orthod Dentofacial Orthop       Date:  1990-11       Impact factor: 2.650

4.  Guidelines for prevention of transmission of human immunodeficiency virus and hepatitis B virus to health-care and public-safety workers.

Authors: 
Journal:  MMWR Suppl       Date:  1989-06-23

5.  Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires.

Authors:  C Pernier; B Grosgogeat; L Ponsonnet; G Benay; M Lissac
Journal:  Eur J Orthod       Date:  2005-02       Impact factor: 3.075

6.  Autoclaving and clinical recycling: effects on mechanical properties of orthodontic wires.

Authors:  M Oshagh; M R Hematiyan; Y Mohandes; M R Oshagh; L Pishbin
Journal:  Indian J Dent Res       Date:  2012 Sep-Oct

7.  The effect of routine steam autoclaving on orthodontic pliers.

Authors:  M Jones; K Pizarro; R Blunden
Journal:  Eur J Orthod       Date:  1993-08       Impact factor: 3.075

8.  A pragmatic approach to asepsis in the orthodontic office.

Authors:  H Starnbach; P Biddle
Journal:  Angle Orthod       Date:  1980-01       Impact factor: 2.079

9.  Compliance with infection control procedures among California orthodontists.

Authors:  J Woo; R Anderson; B Maguire; B Gerbert
Journal:  Am J Orthod Dentofacial Orthop       Date:  1992-07       Impact factor: 2.650

10.  Decontamination of orthodontic bands following size determination and cleaning.

Authors:  P E Benson; C W I Douglas
Journal:  J Orthod       Date:  2007-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.