OBJECTIVE: To determine the results of "biologic fixation" with a minimally invasive plating technique using a newly designed low profile "Scallop" plate in the treatment of pilon fractures.
DESIGN: Retrospective case series.
SETTING: A tertiary referral center. PATIENTS/PARTICIPANTS: Seventeen patients were treated between 1999 and 2001 for a tibial plafond fracture at the Hospital for Special Surgery with a newly designed low-profile plate. Eleven of the fractures (65%) were high-energy injuries. Two fractures were open. INTERVENTION: Staged surgical treatment with open reduction and fixation of the fibular fracture and application of an external fixator was performed in 12 cases. As soon as the soft tissues and swelling allowed, i.e. skin wrinkling, the articular surface was reconstructed and simply reduced, if necessary through an small incision, and the articular block was fixed to the diaphysis using a medially placed, percutaneously introduced flat scallop plate. In the remaining five cases the operation was performed in one session. MAIN OUTCOME MEASUREMENTS: Time to healing and complications including delayed union, non-union, instrument failure, loss of fixation, infection, quality of reduction and number of reoperations were evaluated. Quality of results and outcome were graded using the ankle-hindfoot-scale and a modified rating system.
RESULTS: All patients went on to bony union at an average time of 14 weeks. There were no plate failures or loss of fixation/reduction. Two superficial wound-healing problems resolved with local wound care. At an average follow up of 17 months (range 6-29 months) eight patients (47%) had an excellent result; seven (41%) had a fair result whereas two (12%) had a poor result. The average ankle-hindfoot-score was 86.1 (range 61-100). Four patients have had the hardware removed and one of them is awaiting an ankle arthrodesis.
CONCLUSIONS: Based on these initial results, it appears that a minimally invasive surgical technique including new low profile plate can decrease soft tissue problems while leading to fracture healing and obtaining results comparable with other more recent series. We believe that this new "Scallop Plate" is effective for the treatment of pilon fractures and should be used in conjunction with a staged procedure in the acute trauma setting.

Entities:  

Mesh:

Year:  2006        PMID: 16951937     DOI: 10.1007/s00402-006-0219-1

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  18 in total

1.  Comment on Tong et al.: Two-stage procedure protocol for minimally invasive plate osteosynthesis technique in the treatment of the complex pilon fracture.

Authors:  Da-wei Chen; Bing Li; Guang-rong Yu
Journal:  Int Orthop       Date:  2012-05-13       Impact factor: 3.075

2.  Comment on Kritsaneephaiboon et al.: Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report.

Authors:  Bing Li; Da-wei Chen; Guang-rong Yu; Yun-feng Yang
Journal:  Int Orthop       Date:  2013-05-12       Impact factor: 3.075

3.  Staged protocol in treatment of open distal tibia fracture: using lateral MIPO.

Authors:  Oog Jin Sohn; Dong Hwa Kang
Journal:  Clin Orthop Surg       Date:  2011-02-15

4.  Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients.

Authors:  Rafiq Bhat; Mubashir Maqbool Wani; Shakir Rashid; Nahida Akhter
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-20

5.  A Prospective Study on Functional Outcome of Internal Fixation of Tibial Pilon Fractures with Locking Plate using Minimally Invasive Plate Osteosynthesis Technique.

Authors:  Arjun Ballal; H Ravindranath Rai; Siddharth M Shetty; Lawrence John Mathias; Vikram Shetty; Ashwin Shetty
Journal:  J Clin Diagn Res       Date:  2016-01-01

Review 6.  High-energy tibial pilon fractures: an instructional review.

Authors:  Boris A Zelle; Khang H Dang; Samuel S Ornell
Journal:  Int Orthop       Date:  2019-05-15       Impact factor: 3.075

Review 7.  Evolution in Management of Tibial Pilon Fractures.

Authors:  Jessica Bear; Natalie Rollick; David Helfet
Journal:  Curr Rev Musculoskelet Med       Date:  2018-12

8.  Fractures of the distal tibia treated with polyaxial locking plating.

Authors:  Hong Gao; Chang-Qing Zhang; Cong-Feng Luo; Zu-Bin Zhou; Bing-Fang Zeng
Journal:  Clin Orthop Relat Res       Date:  2008-08-22       Impact factor: 4.176

9.  The Outcomes of Pilon Fracture Treatment: Primary Open Reduction and Internal Fixation Versus Two-stage Approach.

Authors:  Mohammadreza Minator Sajjadi; Adel Ebrahimpour; Mohammad A Okhovatpour; Amin Karimi; Reza Zandi; Amir Sharifzadeh
Journal:  Arch Bone Jt Surg       Date:  2018-09

10.  Clinical and radiological outcome of Gustilo type III open distal tibial and tibial shaft fractures after staged treatment with posterolateral minimally invasive plate osteosynthesis (MIPO) technique.

Authors:  Xiaojian He; Chuanzhen Hu; Kaihua Zhou; Qilin Zhai; Weifeng Wen; Fugen Pan
Journal:  Arch Orthop Trauma Surg       Date:  2018-05-10       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.