Literature DB >> 16950463

Analysis of mitral annulus motion measurements derived from M-mode, anatomic M-mode, tissue Doppler displacement, and 2-dimensional strain imaging.

Shirley Yumi Hayashi1, Britta I Lind, Astrid Seeberger, Marcelo Mazza do Nascimento, Bengt J Lindholm, Lars-Ake Brodin.   

Abstract

BACKGROUND: Left ventricular longitudinal shortening plays an important role in cardiac contraction and can be measured by the mitral annulus motion (MAM) toward the cardiac apex. MAM can be evaluated by conventional M-mode, anatomic M-mode (AM-mode), tissue Doppler displacement (TDD), and 2-dimensional strain imaging (2DSI).
OBJECTIVE: The aim of the study was to compare these 4 different methods for measuring MAM.
METHODS: MAM was evaluated in 25 patients by M-mode, AM-mode, TDD, and 2DSI. Two walls (septal and lateral) in apical 4-chamber view were analyzed.
RESULTS: The angle correction between M-mode and AM-mode was significantly higher in the lateral wall (septum 2.2 +/- 1.6 vs lateral 4.1 +/- 1.6 degrees, P < 0.01). However, with angle correction up to 8 degrees, the measurements obtained were not significantly different from those obtained by M-mode. No significant differences were found among 2DSI, M-mode, and AM-mode either, although all of them were significantly higher in comparison with TDD measurements in both septal (M-mode [11.0 +/- 2.4 mm], AM-mode [11.8 +/- 2.4 mm], 2DSI [11.0 +/- 3.4 mm] vs TDD [9.2 +/- 3.3 mm], P < .01) and lateral (M-mode [11.9 +/- 2.3 mm], AM-mode [12.4 +/- 2.8 mm], 2DSI [10.4 +/- 3.9 mm] vs TDD [8.9 +/- 3.0 mm], P < .05) walls. The +/- 2SD variation from the mean difference in septal and lateral walls were, respectively, between: M-mode and TDD, -2.4 to 5.9 and -2.2 to 8.2 mm; M-mode and 2DSI, -5.7 to 5.7 and -5.8 to 8.7; AM-mode and TDD, -2.5 to 5.6 and -2.7 to 9.6; AM-mode and 2DSI, -5.7 to 5.87 and -5.9 to 9.8 and TDD and 2DSI, -3.2 to 6.6 and -5.3 to 8.4.
CONCLUSIONS: AM-mode and M-mode measurements did not differ significantly. Despite the good correlation among all methods they were not interchangeable. TDD measurements were significantly lower than M-mode, AM-mode, and 2DSI measurements. M-mode and AM-mode are angle dependent and can, therefore, underestimate or overestimate MAM. The new method of 2DSI is promising because it tracks natural acoustic markers and is not angle dependent and, therefore, measures the true local tissue motion.

Entities:  

Mesh:

Year:  2006        PMID: 16950463     DOI: 10.1016/j.echo.2006.04.014

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

Review 1.  Echocardiography in the assessment of left ventricular longitudinal systolic function: current methodology and clinical applications.

Authors:  Valerio Zacà; Piercarlo Ballo; Maurizio Galderisi; Sergio Mondillo
Journal:  Heart Fail Rev       Date:  2010-01       Impact factor: 4.214

Review 2.  Echocardiographic assessment of myocardial ischemia.

Authors:  Roman Leischik; Birgit Dworrak; Fabian Sanchis-Gomar; Alejandro Lucia; Thomas Buck; Raimund Erbel
Journal:  Ann Transl Med       Date:  2016-07

3.  Relationship of multidirectional myocardial strain with radial thickening and ejection fraction and impact of left ventricular hypertrophy: a study in a community-based cohort.

Authors:  Cesare Russo; Zhezhen Jin; Shunichi Homma; Tatjana Rundek; Mitchell S V Elkind; Ralph L Sacco; Marco R Di Tullio
Journal:  Echocardiography       Date:  2013-01-30       Impact factor: 1.724

4.  In vivo dynamic deformation of the mitral valve annulus.

Authors:  Chad E Eckert; Brett Zubiate; Mathieu Vergnat; Joseph H Gorman; Robert C Gorman; Michael S Sacks
Journal:  Ann Biomed Eng       Date:  2009-07-08       Impact factor: 3.934

5.  Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?

Authors:  Aristomenis Manouras; Kambiz Shahgaldi; Reidar Winter; Lars-Ake Brodin; Jacek Nowak
Journal:  Cardiovasc Ultrasound       Date:  2009-03-17       Impact factor: 2.062

Review 6.  Echocardiographic Evaluation of Left Atrial Mechanics: Function, History, Novel Techniques, Advantages, and Pitfalls.

Authors:  Roman Leischik; Henning Littwitz; Birgit Dworrak; Pankaj Garg; Meihua Zhu; David J Sahn; Marc Horlitz
Journal:  Biomed Res Int       Date:  2015-07-07       Impact factor: 3.411

7.  Reference values for fetal tissue velocity imaging and a new approach to evaluate fetal myocardial function.

Authors:  Nina Ne Elmstedt; Jonas Jj Johnson; Britta Bl Lind; Kjerstin Kfw Ferm-Widlund; Lotta Lh Herling; Magnus Mw Westgren; Lars-Åke Lab Brodin
Journal:  Cardiovasc Ultrasound       Date:  2013-08-16       Impact factor: 2.062

8.  The impact of cardiac loading on a novel metric of left ventricular diastolic function in healthy middle-aged adults: Systolic-diastolic coupling.

Authors:  James P MacNamara; Vivek Koshti; Katrin A Dias; Erin Howden; Christopher M Hearon; I-Jou Cheng; Linda S Hynan; Benjamin D Levine; Satyam Sarma
Journal:  Physiol Rep       Date:  2021-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.