Literature DB >> 16949896

A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femur.

R Barkmann1, P Laugier, U Moser, S Dencks, F Padilla, G Haiat, M Heller, C-C Glüer.   

Abstract

Quantitative ultrasound (QUS) measurements at peripheral sites can be used to estimate osteoporotic fracture risk. However, measurements at these sites are less suitable to predict bone mineral density (BMD) or fracture risk at the central skeleton. We investigated whether direct QUS measurements at the femur would allow to estimate dual X-ray absorptiometry (DXA) BMD of the total proximal femur with errors comparable to established DXA accuracy errors. Two independent sets of femora were measured in Kiel (6 f, 4 m, age: 55-90) and Paris (19 f, 20 m age: 45-95) using different benchtop systems in the two laboratories. The femora were scanned in transverse transmission mode using focused US transducers of 500 kHz center frequency. The QUS values were averaged over a region similar to the total hip region of dual X-ray absorptiometry (DXA) measurements. BMD was measured using DXA. SOS and BMD correlated significantly (p<0.0001) in both data sets (R2=0.81-0.93). Correlations between BUA and BMD were also significant at p<0.001, but correlation coefficients were lower (R2=0.61-0.75). Residual errors for the estimation of BMD were 8%-10% for SOS as predictor, and 14%-16% for BUA as predictor. The residual error of 8 to 10% for the estimation of BMD from SOS is comparable to variabilities among different DXA femur subregions and accuracy errors of femoral DXA measurements caused by the impact of soft tissue. It is substantially smaller than the errors of 13% for the estimation of total femur BMD from spine BMD, 14% for the estimation of total femur BMD from calcaneus SOS or 16% for the estimation of ash weight from DXA. The results of the study show that SOS is able to predict total BMD with adequate accuracy. If femoral BMD could be obtained in vivo with comparable accuracy, femoral QUS would be suited for the assessment of bone status at one of the main osteoporotic fracture sites.

Entities:  

Mesh:

Year:  2006        PMID: 16949896     DOI: 10.1016/j.bone.2006.07.010

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  8 in total

1.  Bone turnover markers are correlated with quantitative ultrasound of the calcaneus: 5-year longitudinal data.

Authors:  J Lenora; P Gerdhem; K J Obrant; K K Ivaska
Journal:  Osteoporos Int       Date:  2008-10-23       Impact factor: 4.507

Review 2.  Screening and early diagnosis of osteoporosis through X-ray and ultrasound based techniques.

Authors:  Paola Pisani; Maria Daniela Renna; Francesco Conversano; Ernesto Casciaro; Maurizio Muratore; Eugenio Quarta; Marco Di Paola; Sergio Casciaro
Journal:  World J Radiol       Date:  2013-11-28

3.  Ultrasound to assess bone quality.

Authors:  Kay Raum; Quentin Grimal; Peter Varga; Reinhard Barkmann; Claus C Glüer; Pascal Laugier
Journal:  Curr Osteoporos Rep       Date:  2014-06       Impact factor: 5.096

4.  Effect of gate choice on backscatter difference measurements of cancellous bone.

Authors:  Brent K Hoffmeister; Ann M Viano; Luke C Fairbanks; Sheldon C Ebron; Joseph A McPherson; Matthew T Huber
Journal:  J Acoust Soc Am       Date:  2017-08       Impact factor: 1.840

Review 5.  Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-16       Impact factor: 2.725

6.  Femur ultrasound (FemUS)--first clinical results on hip fracture discrimination and estimation of femoral BMD.

Authors:  R Barkmann; S Dencks; P Laugier; F Padilla; K Brixen; J Ryg; A Seekamp; L Mahlke; A Bremer; M Heller; C C Glüer
Journal:  Osteoporos Int       Date:  2009-08-20       Impact factor: 4.507

Review 7.  New perspectives in echographic diagnosis of osteoporosis on hip and spine.

Authors:  Sergio Casciaro; Francesco Conversano; Paola Pisani; Maurizio Muratore
Journal:  Clin Cases Miner Bone Metab       Date:  2015-10-26

8.  The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study.

Authors:  Cheng-Rui Liu; Hai-Jun Niu; Fang Pu; Ling Wang; Lian-Wen Sun; Yu-Bo Fan; De-Yu Li
Journal:  BMC Musculoskelet Disord       Date:  2012-05-14       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.