Literature DB >> 16944681

Radiation doses to patients receiving computed tomography examinations in British Columbia.

John E Aldrich1, Ana-Maria Bilawich, John R Mayo.   

Abstract

OBJECTIVE: To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada.
METHODS: The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners.
RESULTS: The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen-pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen-pelvis, 1100 mGy cm.
CONCLUSION: Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany.

Entities:  

Mesh:

Year:  2006        PMID: 16944681

Source DB:  PubMed          Journal:  Can Assoc Radiol J        ISSN: 0846-5371            Impact factor:   2.248


  14 in total

Review 1.  Airway imaging in disease: gimmick or useful tool?

Authors:  Peter D Paré; Taishi Nagano; Harvey O Coxson
Journal:  J Appl Physiol (1985)       Date:  2012-05-17

2.  Imaging update: acute colonic diverticulitis.

Authors:  Kristen K Destigter; David P Keating
Journal:  Clin Colon Rectal Surg       Date:  2009-08

Review 3.  A review of femoroacetabular impingement in athletes.

Authors:  Michael J Keogh; Mark E Batt
Journal:  Sports Med       Date:  2008       Impact factor: 11.136

Review 4.  Adult patient radiation doses from non-cardiac CT examinations: a review of published results.

Authors:  I Pantos; S Thalassinou; S Argentos; N L Kelekis; G Panayiotakis; E P Efstathopoulos
Journal:  Br J Radiol       Date:  2011-01-25       Impact factor: 3.039

5.  Patient dose considerations in computed tomography examinations.

Authors:  Ioannis A Tsalafoutas; Georgios V Koukourakis
Journal:  World J Radiol       Date:  2010-07-28

Review 6.  The occult pneumothorax: what have we learned?

Authors:  Chad G Ball; Andrew W Kirkpatrick; David V Feliciano
Journal:  Can J Surg       Date:  2009-10       Impact factor: 2.089

7.  Computed Tomography Angiography in the Assessment of Patients With Stroke/TIA.

Authors:  Bijoy K Menon; Andrew M Demchuk
Journal:  Neurohospitalist       Date:  2011-10

8.  Dose management in CT facility.

Authors:  V Tsapaki; M Rehani
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

9.  Estimating radiation effective doses from whole body computed tomography scans based on U.S. soldier patient height and weight.

Authors:  Robert D Prins; Raymond H Thornton; C Ross Schmidtlein; Brian Quinn; Hung Ching; Lawrence T Dauer
Journal:  BMC Med Imaging       Date:  2011-10-17       Impact factor: 1.930

10.  A national survey on radiation dose in CT in The Netherlands.

Authors:  A J van der Molen; A Schilham; P Stoop; M Prokop; J Geleijns
Journal:  Insights Imaging       Date:  2013-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.