Literature DB >> 16936588

Patella maltracking in posterior-stabilized total knee arthroplasty.

Paul F Lachiewicz1, Elizabeth S Soileau.   

Abstract

Maltracking of the patella component in total knee arthroplasty usually leads to complications such as subluxation, dislocation, fracture, excessive wear, or implant failure. After using a new posterior-stabilized total knee arthroplasty and a specific protocol for the patellofemoral articulation we determined the incidence of lateral retinacular release and patella complications. We retrospectively reviewed 255 consecutive primary posterior-stabilized total knee arthroplasties with an anatomic femoral component and a three-peg offset-dome patella. Component alignment was achieved using Whiteside's lines for the femoral component, the medial border of the tubercle for the tibial component, and previously reported techniques for the patella. Lateral release was performed in 15 knees (6.2%), most of which had excessive preoperative valgus (mean, 15 degrees). There were no reoperations for the patellofemoral joint at a mean followup of 3.7 years (range, 2-7 years). Two patients had asymptomatic osteonecrosis of the patella with complete radiolucent lines, and one patella fracture was treated with immobilization. We believe patella maltracking a largely avoidable problem in total knee arthroplasty. We found a low incidence of lateral retinacular release and patella complications using these components and this protocol for the patellofemoral articulation.

Entities:  

Mesh:

Year:  2006        PMID: 16936588     DOI: 10.1097/01.blo.0000238803.97713.7d

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Combining different rotational alignment axes with navigation may reduce the need for lateral retinacular release in total knee arthroplasty.

Authors:  Gianluca Cinotti; Francesca R Ripani; Pasquale Sessa; Giuseppe Giannicola
Journal:  Int Orthop       Date:  2012-05-16       Impact factor: 3.075

Review 2.  Patellar complications following total knee arthroplasty: a review of the current literature.

Authors:  Angelos Assiotis; Kendrick To; Rhidian Morgan-Jones; Ioannis P Pengas; Wasim Khan
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-07-13

3.  [Digital study on the relationship between position of patellar high point and shape of osteotomy surface in Chinese].

Authors:  Changzhao Li; Peiheng He; Yong Liu; Dongliang Xu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-07-15

Review 4.  Management of patella maltracking after total knee arthroplasty: a systematic review.

Authors:  R Ferri; V Digennaro; A Panciera; B D Bulzacki Bogucki; D Cecchin; M Manzetti; M Brunello; C Faldini
Journal:  Musculoskelet Surg       Date:  2022-10-05

Review 5.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

6.  Effect of smoking and soft tissue release on risk of revision after total knee arthroplasty: a case- control study.

Authors:  Benedict U Nwachukwu; Ellen B Gurary; Vladislav Lerner; Jamie E Collins; Thomas S Thornhill; Elena Losina; Jeffrey N Katz
Journal:  BMC Musculoskelet Disord       Date:  2015-09-09       Impact factor: 2.362

7.  The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements.

Authors:  Raman Maiti; Raelene M Cowie; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-03-25       Impact factor: 1.617

Review 8.  Patella resurfacing during total knee arthroplasty is cost-effective and has lower re-operation rates compared to non-resurfacing.

Authors:  Thomas Parsons; Talal Al-Jabri; Nick D Clement; Nicola Maffulli; Deiary F Kader
Journal:  J Orthop Surg Res       Date:  2021-03-11       Impact factor: 2.359

9.  Patella Strength Characteristics in Cemented vs Press-fit Implants: A Biomechanical Analysis of Initial Stability.

Authors:  Akshar H Patel; J Heath Wilder; John M Weldy; Bailey J Ross; Nathaniel E Kim; Hao Wang; Fernando L Sanchez; William F Sherman
Journal:  Arthroplast Today       Date:  2022-03-15

10.  Component alignment and functional outcome following computer assisted and jig based total knee arthroplasty.

Authors:  Dnyanesh G Lad; Jai Thilak; Mohan Thadi
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.