Literature DB >> 16936430

Impedance cardiography for cardiac output estimation: reliability of wrist-to-ankle electrode configuration.

Oscar Luis Paredes1, Junya Shite, Toshiro Shinke, Satoshi Watanabe, Hiromasa Otake, Daisuke Matsumoto, Yusuke Imuro, Daisuke Ogasawara, Takahiro Sawada, Mitsuhiro Yokoyama.   

Abstract

BACKGROUND: Non-invasive measurement of cardiac output (CO) may become an important modality for the treatment of heart failure. Among the several methods proposed, impedance cardiography (ICG) has gained particular attention. There are 2 basic technologies of ICG: thoracic and whole-body ICG whereby the electrodes are applied either to the chest or to the limbs. The present study is aimed to test the effectiveness of the Non-Invasive Cardiac System (NICaS), a new ICG device working with a wrist-to-ankle configuration. METHODS AND
RESULTS: To evaluate the reliability of NICaS derived CO (NI-CO), 50 CO measurements were taken simultaneously with thermodilution (TD-CO) and modified Fick (Fick-CO) in 35 cardiac patients, with the TD-CO serving as the gold-standard for the evaluation. Overall, 2-tailed Pearson's correlation and Bland-Altman limits of agreement between NI-CO and TD-CO were r=0.91 and -1.06 and 0.68 L/min and between Fick-CO and TD-CO, r=0.80 and -1.52 and 0.88 L/min, respectively. Good correlation was observed in patients with loading conditions altered by nitroglycerin and also in patients with moderate valvular diseases.
CONCLUSION: Agreement between NI-CO and TD-CO is within the boundaries of the FDA guidelines of bio-equivalence. NI-CO is applicable for non-invasive assessment of cardiac function.

Entities:  

Mesh:

Year:  2006        PMID: 16936430     DOI: 10.1253/circj.70.1164

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  9 in total

1.  Cardiac hemodynamics before, during and after elective cesarean section under spinal anesthesia in low-risk women.

Authors:  M Ram; A Lavie; S Lev; Y Blecher; U Amikam; Y Shulman; T Avnon; E Weiner; A Many
Journal:  J Perinatol       Date:  2017-04-13       Impact factor: 2.521

2.  Comparison of stroke volume measurements during hemodialysis using bioimpedance cardiography and echocardiography.

Authors:  Michael J Germain; Jyovani Joubert; Daniel O'Grady; Brian H Nathanson; Yossi Chait; Nathan W Levin
Journal:  Hemodial Int       Date:  2017-08-10       Impact factor: 1.812

3.  The value of non-invasive measurement of cardiac output and total peripheral resistance to categorize significant changes of intradialytic blood pressure: a prospective study.

Authors:  Yunlin Feng; Yurong Zou; Yifei Zheng; Nathan W Levin; Li Wang
Journal:  BMC Nephrol       Date:  2018-11-06       Impact factor: 2.388

4.  Non-invasive hemodynamic profiling of patients undergoing hemodialysis - a multicenter observational cohort study.

Authors:  Keren Doenyas-Barak; Marcia H F G de Abreu; Lucas E Borges; Helcio A Tavares Filho; Feng Yunlin; Zou Yurong; Nathan W Levin; Allen M Kaufman; Shay Efrati; David Pereg; Ilya Litovchik; Shmuel Fuchs; Sa'ar Minha
Journal:  BMC Nephrol       Date:  2019-09-03       Impact factor: 2.388

5.  A Novel Hypertension Management Algorithm Guided by Hemodynamic Data.

Authors:  Barbara Greco; Yossi Chait; Brian H Nathanson; Michael J Germain
Journal:  Kidney Int Rep       Date:  2021-11-27

6.  Comparative study of cardiac output measurement by regional impedance cardiography and thermodilution method in patients undergoing off pump coronary artery bypass graft surgery.

Authors:  Amrita Guha; Dheeraj Arora; Yatin Mehta
Journal:  Ann Card Anaesth       Date:  2022 Jul-Sep

7.  Early post-stress decrease in cardiac performance by impedance cardiography and its relationship to the severity and extent of ischemia by myocardial perfusion imaging.

Authors:  Ronen Goldkorn; Alexey Naimushin; Eli Rozen; Dov Freimark
Journal:  BMC Cardiovasc Disord       Date:  2020-07-31       Impact factor: 2.298

8.  Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™).

Authors:  Anat Lavie; Maya Ram; Shaul Lev; Yair Blecher; Uri Amikam; Yael Shulman; Tomer Avnon; Eran Weiner; Ariel Many
Journal:  BMC Pregnancy Childbirth       Date:  2018-06-14       Impact factor: 3.007

9.  A Phase 1 Randomized Study of Single Intravenous Infusions of the Novel Nitroxyl Donor BMS-986231 in Healthy Volunteers.

Authors:  Douglas Cowart; Robert P Venuti; Kim Lynch; Jeffrey T Guptill; Robert J Noveck; Shi Yin Foo
Journal:  J Clin Pharmacol       Date:  2019-01-31       Impact factor: 3.126

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.