Propagation of anatomical landmark misplacement to knee kinematics: performance of single and double calibration.

Rita Stagni1, Silvia Fantozzi, Angelo Cappello.   

Abstract

Soft tissue artefact and anatomical landmark misplacement have been recognized as the most critical sources of error in gait analysis. The double calibration method was recently proposed to compensate for soft tissue artefact in knee kinematics. This compensation method resulted very effective in the absence of anatomical landmark misplacement. The purpose of the present work was to assess the effectiveness of double calibration in reducing the effects of skin motion artefact on knee rotations and translations when anatomical landmark misplacement is present on the thigh and shank. The double calibration method was used to calculate knee kinematics of two subjects while they performed several motor tasks. The results were compared with those from conventional single calibration. The soft tissue artefact propagated to knee kinematics was quantified by simulating different misplacement errors using both single and double calibration. The double calibration method performed much better than the single calibration one in quantifying knee rotations and particularly translations, with misplacement error up to 15mm superimposed on the anatomical coordinates of the epicondyles. If misplacement errors were limited to just 5mm, the double calibration would be effective in providing kinematics accurate enough for orthopaedic biomechanic applications.

Entities:  

Mesh:

Year:  2006        PMID: 16934471     DOI: 10.1016/j.gaitpost.2006.08.001

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  6 in total

1.  Effects of different technical coordinate system definitions on the three dimensional representation of the glenohumeral joint centre.

Authors:  Amity Cree Campbell; J A Alderson; D G Lloyd; B C Elliott
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

2.  Inertial Sensors in Swimming: Detection of Stroke Phases through 3D Wrist Trajectory.

Authors:  Matteo Cortesi; Andrea Giovanardi; Giorgio Gatta; Anna L Mangia; Sandro Bartolomei; Silvia Fantozzi
Journal:  J Sports Sci Med       Date:  2019-08-01       Impact factor: 2.988

3.  'Outwalk': a protocol for clinical gait analysis based on inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Alberto Ferrari; Pietro Garofalo; Michele Raggi; Angelo Cappello; Adriano Ferrari
Journal:  Med Biol Eng Comput       Date:  2009-11-13       Impact factor: 2.602

4.  First in vivo assessment of "Outwalk": a novel protocol for clinical gait analysis based on inertial and magnetic sensors.

Authors:  Alberto Ferrari; Andrea Giovanni Cutti; Pietro Garofalo; Michele Raggi; Monique Heijboer; Angelo Cappello; Angelo Davalli
Journal:  Med Biol Eng Comput       Date:  2009-11-13       Impact factor: 2.602

5.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors.

Authors:  Josien C van den Noort; Alberto Ferrari; Andrea G Cutti; Jules G Becher; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2012-12-09       Impact factor: 2.602

Review 6.  Sex Dimorphism in Pulmonary Hypertension: The Role of the Sex Chromosomes.

Authors:  Daria S Kostyunina; Paul McLoughlin
Journal:  Antioxidants (Basel)       Date:  2021-05-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.