Literature DB >> 16931255

Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation.

Yeoun Sook Chun1, In Ki Park, Hyeon Il Lee, Jong Ho Lee, Jae Chan Kim.   

Abstract

PURPOSE: To evaluate the changes in laser iridotomies, intraocular pressure (IOP), angle structures, and pupil diameter after implantable contact lens (ICL) (Version 4 Staar Surgical) implantation in myopic Asian eyes.
SETTING: Department of Ophthalmology, Chung-Ang University Yongsan Hospital, Seoul, Korea.
METHODS: The ICL was implanted in 81 eyes of 43 patients with spherical equivalent greater than -6.00 diopters. Gonioscopy examination was performed 1 day after laser iridotomy and 6 and 12 months after ICL implantation. The changes in laser iridotomy sites, IOP, and pupil diameter were also evaluated.
RESULTS: Ten eyes (12.3%) had occlusion or narrowing of the laser iridotomy sites. The angle width was more than 30 degrees in all cases preoperatively but narrowed to less than 20 degrees in 16 eyes (19.8%) 6 months postoperatively. The mean pigment, measured by the semiquantitative method (grade 0 to 4), was 2.03 in the inferior angle, 0.18 in the nasal angle, 0.12 in the temporal angle, and 0.00 in the superior angle 12 months postoperatively. The pigment in all quadrants increased temporally as a result of the laser iridotomy or iris rubbing by the ICL; however, the pigments absorbed gradually and decreased to values before laser iridotomy 12 months postoperatively. There was a temporary increase in IOP from the instillation of steroid eyedrops 1 week and 1 month postoperatively; IOP returned to the preoperative level and remained there 12 months postoperatively. There was a significant decrease in pupil diameter 1 and 3 months postoperatively; the diameter returned to the preoperative size at 6 and 12 months. Pigment dispersion syndrome and pigmentary glaucoma were not seen.
CONCLUSION: Implantation of the ICL narrowed the angle width but did not increase trabecular pigmentation compared with values after laser iridotomy, indicating ICL implantation is safe regardless of the pigmentary changes in the trabecular meshwork.

Entities:  

Mesh:

Year:  2006        PMID: 16931255     DOI: 10.1016/j.jcrs.2006.04.023

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  18 in total

1.  Three-year follow-up of subjective vault following myopic implantable collamer lens implantation.

Authors:  José F Alfonso; Carlos Lisa; A Abdelhamid; Paulo Fernandes; Jorge Jorge; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

2.  Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia.

Authors:  Salem Almalki; Abdullah Abubaker; Nasser A Alsabaani; Deepak P Edward
Journal:  Int Ophthalmol       Date:  2015-08-12       Impact factor: 2.031

Review 3.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

4.  Pseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia.

Authors:  Michael V McCaughey; Thomas Mifflin; Carlton R Fenzl; Jason Goldsmith; Majid Moshirfar
Journal:  Open J Ophthalmol       Date:  2014-11

5.  Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter.

Authors:  Arvind Venkataraman; Sapna K Mardi; Sarita Pillai
Journal:  Indian J Ophthalmol       Date:  2010 May-Jun       Impact factor: 1.848

6.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

7.  Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes.

Authors:  Erik L Mertens
Journal:  Clin Ophthalmol       Date:  2011-03-14

8.  Artiflex versus STAAR implantable contact lenses for correction of high myopia.

Authors:  Mohammad Ghoreishi; Amin Masjedi; Kobra Nasrollahi; Aminhossein Rahgozar; Keivan Jenab; Hamid Fesharaki
Journal:  Oman J Ophthalmol       Date:  2011-09

9.  Comparison of peripheral iridectomy methods for posterior chamber phakic intraocular lens implantation in patients with brown irides.

Authors:  Yan Wu; Fei Han; Yan Quan; Wei Jiang; Hengdi Zhang; Tao Luo
Journal:  BMC Ophthalmol       Date:  2016-05-05       Impact factor: 2.209

10.  Pupil Diameter Changes in High Myopes after Collamer Lens Implantation.

Authors:  Dan Li; Yabo Yang; Caipei Su; Houfa Yin; Xue Liu
Journal:  Optom Vis Sci       Date:  2015-12       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.