Literature DB >> 16929430

Stepwise introduction of a bone-conserving osseointegrated hip arthroplasty using RSA and a randomized study: I. Preliminary investigations--52 patients followed for 3 years.

Lars V Carlsson1, Björn E J Albrektsson, Björn G Albrektsson, Tomas O Albrektsson, C Magnus Jacobsson, Warren Macdonald, Lars Regnér, Tord Röstlund, Lars R Weidenhielm.   

Abstract

BACKGROUND: We developed a total hip system using osseointegration guidelines, a metaphyseal-loading proximal femoral replacement in the retained neck and a dual-geometry titanium shell in the acetabulum. PATIENTS AND METHODS: A randomized controlled clinical trial was undertaken in 52 patients (53 hips), using the cemented Spectron stem and cementless Harris-Galante II cup as control implants (24 patients in experimental group, 29 control patients). Clinical measures of Harris Hip Score (HHS), pain score and radiostereometric analysis (RSA) at regular intervals for up to three years were used to monitor progress.
RESULTS: No statistically significant differences were found in HHS and pain score; the stability of the cementless experimental implant was also comparable to that of the cemented controls by RSA. 3 revisions were required for migration in the experimental group and 1 was required for component dislocation in the control group.
INTERPRETATION: Our findings indicate the practicality of osseointegration of titanium implants, but suggest that current performance is inadequate for clinical introduction. However, the stable fixation achieved in the retained neck in the majority of patients is indicative of osseointegration. This finding will encourage technical and design improvements for enhancement of clinical osseointegration and should also encourage further study. Periprosthetic osteolysis might be avoided by the establishment and maintenance of direct implant-bone connection: "osseointegration".

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16929430     DOI: 10.1080/17453670610012601

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  4 in total

Review 1.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

2.  Total Hip Arthroplasty by the Direct Anterior Approach Using a Neck-preserving Stem: Safety, efficacy and learning curve.

Authors:  Aditya Khemka; Omar Mograby; Sarah J Lord; Zelda Doyle; Munjed Al Muderis
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

3.  A comparison of short-stem prostheses and conventional stem prostheses in primary total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Zhen Zhang; Qiqi Xing; Jingyi Li; Zichao Jiang; Yixiao Pan; Yihe Hu; Long Wang
Journal:  Ann Transl Med       Date:  2021-02

4.  Are short-stem prostheses superior to conventional stem prostheses in primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials.

Authors:  Hao-Dong Liang; Wei-Yi Yang; Jian-Ke Pan; He-Tao Huang; Ming-Hui Luo; Ling-Feng Zeng; Jun Liu
Journal:  BMJ Open       Date:  2018-09-21       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.