Literature DB >> 16924986

Effect of water storage on the bonding effectiveness of 6 adhesives to Class I cavity dentin.

Jan De Munck1, Kenichi Shirai, Yasuhiro Yoshida, Satoshi Inoue, Kirsten Van Landuyt, Paul Lambrechts, Kazuomi Suzuki, Hideaki Shintani, Bart Van Meerbeek.   

Abstract

Adhesive-dentin interfaces degrade with time. This study determined the effect water storage may have on the bonding effectiveness of adhesives to occlusal Class I cavity-bottom dentin. Six adhesives, all representing contemporary classes of adhesives, were applied: a 3-step (OptiBond FL, Kerr) and 2-step (Scotchbond 1*, 3M ESPE) etch-and-rinse adhesive, a 2-step (Clearfil SE, Kuraray) and 1-step (Adper prompt, 3M ESPE) self-etch adhesive and a 2-step (FujiBond LC, GC) and 1-step (Reactmer, Shofu) resin-modified glass-ionomer adhesive. Bonding effectiveness was assessed by microtensile bond strength testing (MTBS) and electron microscopy (Feg-SEM and TEM). The MTBS was determined after 1 day and 1 year water storage of the entire restored cavity (indirect exposure of the adhesive-dentin interface to water) and prepared microTBS-beams (direct exposure of the adhesive-dentin interface to water). The hypotheses tested were: (1) resin-dentin bonds formed at the bottom of Class I cavities resist 1-year water storage and (2) an adjacent composite-enamel bond protects the composite-dentin bond against degradation. Non-parametric Kruskal-Wallis analysis statistically analyzed the microTBSs. The first hypothesis was rejected, as only the microTBS of OptiBond FL and Clearfil SE did not significantly decrease after 1-year direct and/or indirect water storage. The second hypothesis was corroborated, as the bonding effectiveness of most simplified adhesives (Scotchbond 1, Adper Prompt, FujiBond LC and Reactmer) approached 0 (because of the frequent pre-testing failures) after 1-year direct water exposure. The second hypothesis concluded that the 3-step etch-and-rinse adhesive must still be regarded the "gold standard." Though microTBS decreased significantly, Clearfil SE, as a 2-step self-etch adhesive, was the only simplified adhesive to perform reliably after 1-year direct water exposure.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16924986     DOI: 10.2341/05-57

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  12 in total

1.  Distinct photopolymerization efficacy on dentin of self-etch adhesives.

Authors:  Y Zhang; Y Wang
Journal:  J Dent Res       Date:  2012-06-26       Impact factor: 6.116

2.  A 13-year clinical evaluation of two three-step etch-and-rinse adhesives in non-carious class-V lesions.

Authors:  Marleen Peumans; Jan De Munck; Kirsten L Van Landuyt; Andre Poitevin; Paul Lambrechts; Bart Van Meerbeek
Journal:  Clin Oral Investig       Date:  2010-10-08       Impact factor: 3.573

3.  Hydroxyapatite effect on photopolymerization of self-etching adhesives with different aggressiveness.

Authors:  Ying Zhang; Yong Wang
Journal:  J Dent       Date:  2012-03-22       Impact factor: 4.379

Review 4.  Durability of bonds and clinical success of adhesive restorations.

Authors:  Ricardo M Carvalho; Adriana P Manso; Saulo Geraldeli; Franklin R Tay; David H Pashley
Journal:  Dent Mater       Date:  2012-01       Impact factor: 5.304

5.  Effect of reactive and un-reactive substrates on photopolymerization of self-etching adhesives with different aggressiveness.

Authors:  Ying Zhang; Yong Wang
Journal:  Dent Mater J       Date:  2013       Impact factor: 2.102

6.  Effect of application mode on interfacial morphology and chemistry between dentine and self-etch adhesives.

Authors:  Ying Zhang; Yong Wang
Journal:  J Dent       Date:  2012-11-12       Impact factor: 4.379

7.  Photopolymerization of phosphoric acid ester-based self-etch dental adhesives.

Authors:  Ying Zhang; Yong Wang
Journal:  Dent Mater J       Date:  2013       Impact factor: 2.102

8.  Effect of Dentin Wetness on the Bond Strength of Universal Adhesives.

Authors:  An-Na Choi; Ji-Hye Lee; Sung-Ae Son; Kyoung-Hwa Jung; Yong Hoon Kwon; Jeong-Kil Park
Journal:  Materials (Basel)       Date:  2017-10-25       Impact factor: 3.623

9.  Short-and long-term bond strengths of a gold standard two-step self-etch adhesive system to dentin: a preliminary study.

Authors:  Safa Tuncer; Neslihan Tekce; Dial Pashaev; Mustafa Demirci; Canan Baydemir
Journal:  J Istanb Univ Fac Dent       Date:  2015-04-29

10.  Microleakage at enamel and dentin margins with a bulk fills flowable resin.

Authors:  Nicola Scotti; Allegra Comba; Alberto Gambino; Davide Salvatore Paolino; Mario Alovisi; Damiano Pasqualini; Elio Berutti
Journal:  Eur J Dent       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.