Literature DB >> 16924446

[The foundations of computer assisted surgery].

F Langlotz1, L-P Nolte, M Tannast.   

Abstract

Using navigation systems in general orthopaedic surgery and, in particular, knee replacement is becoming more and more accepted. This paper describes the basic technological concepts of modern computer assisted surgical systems. It explains the variation in currently available systems and outlines research activities that will potentially influence future products. In general, each navigation system is defined by three components: (1) the therapeutic object is the anatomical structure that is operated on using the navigation system, (2) the virtual object represents an image of the therapeutic object, with radiological images or computer generated models potentially being used, and (3) last but not least, the navigator acquires the spatial position and orientation of instruments and anatomy thus providing the necessary data to replay surgical action in real-time on the navigation system's screen.

Mesh:

Year:  2006        PMID: 16924446     DOI: 10.1007/s00132-006-0993-z

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  18 in total

1.  Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique.

Authors:  Lars Perlick; Holger Bäthis; Carsten Perlick; Christian Lüring; Markus Tingart; Joachim Grifka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-04-08       Impact factor: 4.342

2.  Computer assisted navigation in total knee arthroplasty: comparison with conventional methods.

Authors:  Kevin C Anderson; Knute C Buehler; David C Markel
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

3.  Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA.

Authors:  Denis Crottet; Thomas Maeder; Daniel Fritschy; Hannes Bleuler; Lutz P Nolte; Ion P Pappas
Journal:  IEEE Trans Biomed Eng       Date:  2005-09       Impact factor: 4.538

4.  Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system.

Authors:  Jean-Yves Jenny; Cyril Boeri; Frédéric Picard; François Leitner
Journal:  Comput Aided Surg       Date:  2004

5.  [Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study].

Authors:  P R Aldinger; H S Gill; U Schlegel; M Schneider; M Clauss; J W Goodfellow; D W Murray; S J Breusch
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

6.  Computer assisted knee replacement.

Authors:  S L Delp; S D Stulberg; B Davies; F Picard; F Leitner
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

7.  Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction.

Authors:  R Hofstetter; M Slomczykowski; C Krettek; G Köppen; M Sati; L P Nolte
Journal:  Comput Aided Surg       Date:  2000

8.  Computer-assisted pedicle screw fixation. A feasibility study.

Authors:  L P Amiot; H Labelle; J A DeGuise; M Sati; P Brodeur; C H Rivard
Journal:  Spine (Phila Pa 1976)       Date:  1995-05-15       Impact factor: 3.468

9.  [Soft tissue management in knees with varus deformity. Computer-assisted sequential medial ligament release].

Authors:  C Lüring; T Hüfner; L Perlick; H Bäthis; C Krettek; J Grifka
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

10.  Computer assisted orthopaedic surgery. Image guided and robotic assistive technologies.

Authors:  A M DiGioia; B Jaramaz; B D Colgan
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

View more
  1 in total

1.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.