Literature DB >> 16922270

Development of a validated HPLC method for the determination of four penicillin antibiotics in pharmaceuticals and human biological fluids.

Victoria F Samanidou1, Evaggelia N Evaggelopoulou, Ioannis N Papadoyannis.   

Abstract

A quantitative method for the determination of four penicillin antibiotics, amoxicillin (AMO), oxacillin (OXA), cloxacillin (CLO), and dicloxacillin (DICLO), has been developed. Separation was achieved on an Inertsil ODS-3 (250 x 4 mm, 5 microm) column after selective extraction of penicillin drugs from biological matrices by means of SPE. Gradient elution with a mobile phase consisting of 0.1% TFA (pH 1) and ACN, and PDA detection with monitoring at 240 nm was applied. Salicylic acid (5 ng/microL) was used as the internal standard. RP-8 Adsorbex Merck cartridges provided high absolute recoveries (98-101%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <10%. Recoveries from biological samples ranged from 91 to 103%. The detection limits were estimated as 3.3 ng for AMO, OXA, and CLO, and 6.6 for DICLO in blood plasma. LOD in whole blood and urine was 6.6 ng. Injection volume was 20 microL. The method was applied to commercially available AMO containing pharmaceuticals and spiked biological matrices. The method was also applied to biological samples after AMO oral administration, where the drug was successfully identified and quantified.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16922270     DOI: 10.1002/jssc.200600081

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  7 in total

1.  Therapeutic drug monitoring of antimicrobials.

Authors:  Jason A Roberts; Ross Norris; David L Paterson; Jennifer H Martin
Journal:  Br J Clin Pharmacol       Date:  2012-01       Impact factor: 4.335

2.  Simultaneous determination of 12 beta-lactam antibiotics in human plasma by high-performance liquid chromatography with UV detection: application to therapeutic drug monitoring.

Authors:  Marie-Clémence Verdier; Olivier Tribut; Pierre Tattevin; Yves Le Tulzo; Christian Michelet; Danièle Bentué-Ferrer
Journal:  Antimicrob Agents Chemother       Date:  2011-07-25       Impact factor: 5.191

3.  Comparative Study of RP-HPLC and UV Spectrophotometric Techniques for the Simultaneous Determination of Amoxicillin and Cloxacillin in Capsules.

Authors:  Do T Giang; Vu D Hoang
Journal:  J Young Pharm       Date:  2010-04

4.  Comparison between a Direct-Flow SPR Immunosensor for Ampicillin and a Competitive Conventional Amperometric Device: Analytical Features and Possible Applications to Real Samples.

Authors:  Mauro Tomassetti; Giovanni Merola; Elisabetta Martini; Luigi Campanella; Gabriella Sanzò; Gabriele Favero; Franco Mazzei
Journal:  Sensors (Basel)       Date:  2017-04-10       Impact factor: 3.576

5.  A Flow SPR Immunosensor Based on a Sandwich Direct Method.

Authors:  Mauro Tomassetti; Giorgia Conta; Luigi Campanella; Gabriele Favero; Gabriella Sanzò; Franco Mazzei; Riccarda Antiochia
Journal:  Biosensors (Basel)       Date:  2016-05-13

Review 6.  Determination and Identification of Antibiotic Drugs and Bacterial Strains in Biological Samples.

Authors:  Katarzyna Pauter; Małgorzata Szultka-Młyńska; Bogusław Buszewski
Journal:  Molecules       Date:  2020-05-31       Impact factor: 4.411

7.  Construction of an Electrochemical Receptor Sensor Based on Graphene/Thionine for the Sensitive Determination of β-Lactam Antibiotics Content in Milk.

Authors:  Lei Wang; Liyun Zhang; Yuke Wang; Yahong Ou; Xu Wang; Yuanhu Pan; Yulian Wang; Lingli Huang; Guyue Cheng; Shuyu Xie; Dongmei Chen; Yanfei Tao
Journal:  Int J Mol Sci       Date:  2020-05-07       Impact factor: 5.923

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.