Literature DB >> 16919969

The effect of ultrasound probe orientation on muscle architecture measurement.

Marc Klimstra1, Jim Dowling, Jennifer L Durkin, Maureen MacDonald.   

Abstract

The purpose of this paper was to examine how muscle architecture parameter (MAP) measurements made using brightness-mode ultrasonography (BMU) differ based on probe orientation. The human tibialis anterior muscle was imaged from nine different probe orientations during concentric contractions at four joint angles to determine the effect of probe orientation on the measurement of muscle architecture parameters. Ankle dorsi-flexion torque, tibialis anterior electromyography (EMG), and measures of MAP including fascicle length (FL), pennation angle (PA) and muscle thickness (MT) were collected. Statistically significant differences were found between joint angles for measures of FL and PA and between probe orientations for measures of FL and MT. A comparison of actual MAP values to a geometric model used by researchers to determine an ideal probe orientation show that the actual values vary to a greater extent and do not follow the trend predicted by the model. The results suggest that ultrasound probe orientation affects measures of MAP but the effect either cannot be predicted from a geometric model and/or the error in the measurement technique does not allow a comparison.

Entities:  

Mesh:

Year:  2006        PMID: 16919969     DOI: 10.1016/j.jelekin.2006.04.011

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  31 in total

1.  Incline plyometrics-induced improvement of jumping performance.

Authors:  Theodoros M Kannas; Eleftherios Kellis; Ioannis G Amiridis
Journal:  Eur J Appl Physiol       Date:  2011-10-29       Impact factor: 3.078

2.  Muscle gearing during isotonic and isokinetic movements in the ankle plantarflexors.

Authors:  Avleen Randhawa; Meghan E Jackman; James M Wakeling
Journal:  Eur J Appl Physiol       Date:  2012-07-10       Impact factor: 3.078

3.  Differential changes in muscle architecture and neuromuscular fatigability induced by isometric resistance training at short and long muscle-tendon unit lengths.

Authors:  Ryota Akagi; Avery Hinks; Geoffrey A Power
Journal:  J Appl Physiol (1985)       Date:  2020-06-18

4.  Age-related greater Achilles tendon compliance is not associated with larger plantar flexor muscle fascicle strains in senior women.

Authors:  R Csapo; V Malis; J Hodgson; S Sinha
Journal:  J Appl Physiol (1985)       Date:  2014-02-06

5.  Motor Impairment-Related Alterations in Biceps and Triceps Brachii Fascicle Lengths in Chronic Hemiparetic Stroke.

Authors:  Christa M Nelson; Wendy M Murray; Julius P A Dewald
Journal:  Neurorehabil Neural Repair       Date:  2018-08-23       Impact factor: 3.919

6.  Influence of Ultrasound Transducer Tilt in the Cranial and Caudal Directions on Measurements of Inter-Rectus Distance in Parous Women.

Authors:  Nicole F Hills; Nadia Keshwani; Linda McLean
Journal:  Physiother Can       Date:  2018       Impact factor: 1.037

7.  Image acquisition stability of fixated musculoskeletal sonography in an exercise setting: a quantitative analysis and comparison with freehand acquisition.

Authors:  H Maarten Heres; Marloes Sjoerdsma; Thijs Schoots; Marcel C M Rutten; Frans N van de Vosse; Richard G P Lopata
Journal:  J Med Ultrason (2001)       Date:  2019-11-07       Impact factor: 1.314

8.  Intra-rater reliability of transversus abdominis measurement by a novice examiner: Comparison of "freehand" to "probe force device" method of real-time ultrasound imaging.

Authors:  Vanessa L Kennedy; Carol A Flavell; Kenji Doma
Journal:  Ultrasound       Date:  2019-02-25

9.  In vivo measurements of biceps brachii and triceps brachii fascicle lengths using extended field-of-view ultrasound.

Authors:  Christa M Nelson; Julius P A Dewald; Wendy M Murray
Journal:  J Biomech       Date:  2016-04-01       Impact factor: 2.712

10.  Reliability of a semi-automated algorithm for the vastus lateralis muscle architecture measurement based on ultrasound images.

Authors:  Robert Marzilger; Kirsten Legerlotz; Chrystalla Panteli; Sebastian Bohm; Adamantios Arampatzis
Journal:  Eur J Appl Physiol       Date:  2017-12-06       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.