Literature DB >> 16918135

Comparison of dose distributions in IMRT planning using the gamma function.

C Andenna1, M Benassi, B Caccia, S Marzi, M Pedrini, C Zicari.   

Abstract

Intensity-modulated radiotherapy (IMRT) (1) is an advanced form of 3-D conformal radiotherapy. It uses non uniform spatial modifications in the intensity of the beams across the irradiated field. Consequently, it is necessary to develop sophisticated tools to compare measured and calculated dose distributions in order to verify the accuracy of the results of the planned dose distribution. Different methods have been developed to evaluate the accordance between measured and calculated doses, such as the point-to-point dose difference or the evaluation of the distance between two closed points having the same dose value (2-4). The verification method proposed by Low (5-7) seems to be more complete since it takes into account both the dose difference (DD) and the distance to agreement (DTA), allowing to define a "score", the gamma value, at each point of interest. A software tool (DDE: Dose Distribution Evaluator), based on Low's method, to evaluate the agreement between dose distribution matrices has been implemented. In particular, the proposed gamma curve, as a function of the isodose levels, gives real-time information useful for decision making about the treatment plan. The paper describes the software, and reports the obtained results in a simple geometry and in several clinical cases (head-neck and prostate). Comparison between measured data (film and MapCheck) and calculated data (CadPlan) using DDE has shown very good agreements. Thanks to its higher resolution, film dosimetry showed better accuracy than the MapCheck technique. Similar results can be obtained also with the MapCheck technique when proper measurement methods are used.

Mesh:

Year:  2006        PMID: 16918135

Source DB:  PubMed          Journal:  J Exp Clin Cancer Res        ISSN: 0392-9078


  3 in total

1.  Exit fluence analysis using portal dosimetry in volumetric modulated arc therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Dhanabalan Rajasekaran; Muniyappan Kannan; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-15

2.  Dosimetric impact of different multileaf collimators on prostate intensity modulated treatment planning.

Authors:  Lucia Clara Orlandini; Margherita Betti; Christian Fulcheri; Marianna Coppola; Luca Cionini
Journal:  Rep Pract Oncol Radiother       Date:  2015-09-29

3.  Radiation dose verification using real tissue phantom in modern radiotherapy techniques.

Authors:  Om Prakash Gurjar; S P Mishra; Virendra Bhandari; Pankaj Pathak; Prapti Patel; Garima Shrivastav
Journal:  J Med Phys       Date:  2014-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.