Literature DB >> 16916877

Fibrin glue-assisted glaucoma drainage device surgery.

M Y Kahook1, R J Noecker.   

Abstract

AIM: To describe the use of fibrin glue as a suture substitute for portions of glaucoma drainage device (GDD) surgery.
METHODS: Retrospective non-randomised case-control study reviewing 28 consecutive cases of GDD implantation using traditional suture material compared with 14 consecutive cases of GDD implantation using Tisseel fibrin glue (Baxter AG, Vienna, Austria) for portions of the procedure. The fibrin glue was used to close the conjunctiva, secure the pericardium patch graft and secure the tube to the sclera. Three-month follow-up data for each group as well as data on operating times, postoperative conjunctival inflammation, drugs used for glaucoma and intraocular pressure (IOP) were evaluated. Statistical analysis was carried out using analysis of variance.
RESULTS: The mean (SD) age of the patients in the suture group (17 men and 11 women) was 56.6 (10.5) years and that in the Tisseel-assisted group (8 men and 6 women) was 54.7 (8.6) years (p = 0.56). No significant differences were observed in IOP levels at any time point between the two groups. No significant differences were found for the need for postoperative glaucoma drops or postoperative complication rates in both groups. Conjunctival inflammation was more pronounced in the suture group (p = 0.002) using a standard scale for comparison. The mean (SD) time of surgery was significantly less for the Tisseel-assisted group, 15.0 (3.11) min, than for the suture group, 25.93 (4.04) min (p<0.001).
CONCLUSIONS: Tisseel fibrin glue seems to be a safe substitute for some of the sutures used in GDD surgery. Use of Tisseel seems to have no effect on IOP control or complications, whereas it considerably improved postoperative conjunctival inflammation and reduced time of surgery. Further studies are needed to better understand the role of fibrin glue in GDD implantation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16916877      PMCID: PMC1857532          DOI: 10.1136/bjo.2006.101253

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  The use of fibrin glue in mucous membrane grafting of the fornix.

Authors:  M T Watts; R Collin
Journal:  Ophthalmic Surg       Date:  1992-10

2.  Fibrin glue: an alternative method of wound closure in glaucoma surgery.

Authors:  F O'Sullivan; R Dalton; C K Rostron
Journal:  J Glaucoma       Date:  1996-12       Impact factor: 2.503

3.  Conjunctival closure in strabismus surgery: Vicryl versus fibrin glue.

Authors:  B Biedner; G Rosenthal
Journal:  Ophthalmic Surg Lasers       Date:  1996-11

4.  A fibrin sealant for perforated and preperforated corneal ulcers.

Authors:  F M Lagoutte; L Gauthier; P R Comte
Journal:  Br J Ophthalmol       Date:  1989-09       Impact factor: 4.638

5.  Fibrin sealant in the management of complicated hypotony after trabeculectomy.

Authors:  R Grewing; U Mester
Journal:  Ophthalmic Surg Lasers       Date:  1997-02

6.  Fibrin glue as a suture substitute: histological evaluation of trabeculectomy in rabbit eyes.

Authors:  Irit Bahar; Dov Weinberger; Moshe Lusky; Rahamim Avisar; Anat Robinson; Dan Gaton
Journal:  Curr Eye Res       Date:  2006-01       Impact factor: 2.424

7.  Fibrin glue for preventing immediate postoperative hypotony following glaucoma drainage implant surgery.

Authors:  Juha Välimäki
Journal:  Acta Ophthalmol Scand       Date:  2006-06

8.  Management of bleb leaks after glaucoma filtering surgery. Use of autologous fibrin tissue glue as an alternative.

Authors:  S G Asrani; J T Wilensky
Journal:  Ophthalmology       Date:  1996-02       Impact factor: 12.079

  8 in total
  12 in total

1.  Surgical Reconstruction of Ocular Surface Tumors Using Fibrin Sealant Tissue Adhesive.

Authors:  Aline Roseane Queiroz de Paiva; Larissa Abreu de Azevedo Fraga; Virgínia Laura Lucas Torres
Journal:  Ocul Oncol Pathol       Date:  2016-03-15

2.  Optimization of Fibrin Glue Spray Systems for Ophthalmic Surgery.

Authors:  Shyam S Chaurasia; Ravi Champakalakshmi; Romesh I Angunawela; Donald T Tan; Jodhbir S Mehta
Journal:  Transl Vis Sci Technol       Date:  2012-06-29       Impact factor: 3.283

3.  Our experience of fibrin sealant-assisted implantation of Ahmed glaucoma valve.

Authors:  Nikhil S Choudhari; Aditya Neog; Anuj Sharma; Geetha K Iyer; Bhaskar Srinivasan
Journal:  Indian J Ophthalmol       Date:  2013 Jan-Feb       Impact factor: 1.848

4.  A new manner of reporting pressure results after glaucoma surgery.

Authors:  Constantin-Dan Bordeianu; Cristina-Eugenia Ticu
Journal:  Clin Ophthalmol       Date:  2011-12-30

5.  Our experience of fibrin sealant-assisted implantation of Ahmed glaucoma valve.

Authors:  Subashini Kaliaperumal
Journal:  Indian J Ophthalmol       Date:  2013-06       Impact factor: 1.848

6.  Novel use of fibrin sealant for scleral suture free placement of a glaucoma drainage device in advanced scleral thinning.

Authors:  Justin D Harvey; Ronald L Gross; Brian D McMillan
Journal:  Am J Ophthalmol Case Rep       Date:  2017-10-23

7.  Surgical outcomes associated with a sutureless drainage valve implantation procedure in patients with refractory glaucoma.

Authors:  Caroline N Pham; Nathan M Radcliffe; Daniel M Vu
Journal:  Clin Ophthalmol       Date:  2018-12-12

8.  Intracameral Air and Fibrin Glue for the Management of Late Bleb Leak following Glaucoma Surgery.

Authors:  Mohammed R Hayat; Fatema S Mollah; Kamal Kishore
Journal:  Case Rep Ophthalmol       Date:  2019-01-24

9.  Authors' reply.

Authors:  N S Choudhari; A Neog; A Sharma; G K Iyer; B Srinivasan
Journal:  Indian J Ophthalmol       Date:  2013-06       Impact factor: 1.848

Review 10.  Improving Glaucoma Surgical Outcomes with Adjunct Tools.

Authors:  Louise J Lu; Laura Hall; Ji Liu
Journal:  J Curr Glaucoma Pract       Date:  2018-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.